Installation Requirements

3.1.4 Temperature rise under several conditions

Table 3.2 Temperature at each measuring point (Reference)

[Ambient atmospheric temperature of the optical disk drive:

45°C]

(°C)

 

 

Measurement point

Ready

 

Random seek

Criteria

 

 

 

 

 

 

 

 

Inside cartridge

47°C

 

 

54°C

55°C

 

 

 

 

 

 

 

 

IC (controller) surface

51°C

 

 

68°C

90°C

 

 

 

 

 

 

 

 

IC (read amp.) surface

48°C

 

 

90°C

95°C

 

 

 

 

 

 

 

 

IC (power amp.) surface

47°C

 

 

78°C

90°C

 

 

 

 

 

 

 

 

Thermal sensor

47°C

 

 

55°C

 

 

 

 

 

 

 

Notes:

1.The above data are data estimated as they were measured where the temperature surrounding the equipment was kept at 45 °C, using that at 25 °C. They are not the same as the data obtained from measurements using the exclusive box in which the equipment is normally used.

2.When using the box, the ambient temperature around the equipment will differ depending on the air circulation conditions of the box, and the temperature rise inside the cartridge will differ because of this, so please exercise caution.

3.1.5 Air purity

Air purity in the device environment is expressed by the number of dust particles per unit area and must be class 5 millions (equivalent to 0.15 mg/m3) or less. (Class 5 millions: 5 millions dust particles of 0.5 um dia. or larger per cubic foot)

3-4

C156-E224-01EN

Page 50
Image 50
Fujitsu MCJ3230SS Temperature rise under several conditions, Air purity, Temperature at each measuring point Reference