Fujitsu MPB3021AT manual 6 Address translation example in LBA mode 6.3 Power Save, Power save mode

Models: MPB3043AT MPB3021AT MPB3052AT MPB3032AT MPB3054AT

1 180
Download 180 pages 25.81 Kb
Page 163
Image 163
Figure 6.6 Address translation (example in LBA mode)

(2)LBA mode

Logical address assignment in the LBA mode starts from physical cylinder 0, physical head 0, and physical sector 1. The logical address is advanced at the subsequent sector from the last sector of the current track. The first physical sector of the subsequent physical track is the consecutive logical sector from the last sector of the current physical track.

Figure 6.6 shows an example of (assuming there is no track skew).

Physical sector

1 2 3

Physical cylinder 0

LBA0 LBA1 LBA2

Physical head 0

1 2 3

Physical cylinder 1

LBA0 LBA1 LBA2

Physical head 0

ex: Zone 0

Physical parameter

– Physical sector: 1 to 300

Figure 6.6 Address translation (example in LBA mode)

6.3Power Save

299

300

 

LBA

LBA

 

298

299

 

 

 

299

300

 

LBA

LBA

 

298

299

 

 

 

The host can change the power consumption state of the device by issuing a power command to the device.

6.3.1Power save mode

There are four types of power consumption state of the device including active mode where all circuits are active.

In the power save mode, power supplying to the part of the circuit is turned off. There are three types of power save modes:

Idle mode

Standby mode

Sleep mode

The drive moves from the Active mode to the idle mode by itself.

6 - 8

C141-E045-02EN

Page 163
Image 163
Fujitsu MPB3021AT, MPB3054AT, MPB3032AT, MPB3052AT 6 Address translation example in LBA mode 6.3 Power Save, Power save mode