Table 5.4 Information to be read by IDENTIFY DEVICE command (1 of 3)

Word

Value

 

Description

0

X‘0C5A’

General Configuration *1

 

1

X‘1176’

Number of cylinders

MPB3021AT: X‘1176’

 

X‘1A30’

 

MPB3032AT: X‘1A30’

 

X‘22EC’

 

MPB3043AT: X‘22EC’

 

X‘2A62’

 

MPB3052AT: X‘2A62’

 

X‘3462’

 

MPB3064AT: X‘3462’

2

X‘0000’

Reserved

 

3

X‘000F’

Number of Heads

 

4

X‘0000’

Retired

 

5

X‘0000’

Retired

 

6

X‘003F’

Number of sectors per track

 

7-9

X‘000000000000’

Retired

 

10-19

Serial number (ASCII code) *2

 

20-21

X‘00000000’

Retired

 

22

X‘0004’

Number of ECC bytes transferred at READ LONG or WRITE LONG command

23-26

Firmware revision (ASCII code) *3

 

27-46

Model number (ASCII code) *4

 

47

X‘8010’

Maximum number of sectors per interrupt on READ/WRITE MULTIPLE command

48

X‘0000’

Reserved

 

49

X‘0B00’

Capabilities *5

 

50

X‘0000’

Reserved

 

51

X‘0200’

PIO data transfer mode *6

 

52

X‘0000’

Retired

 

53

X‘0003’ or

Enable/disable setting of words 54-58, 64-70 and 88 *7

 

X‘0007’

 

 

54

(Variable)

umber of current Cylinders

 

55

(Variable)

Number of current Head

 

56

(Variable)

Number of current sectors per track

 

57-58

(Variable)

Total number of current sectors

 

59

*8

Transfer sector count currently set by READ/WRITE MULTIPLE command

60-61

X‘00407496’

Total number of user addressable sectors (LBA mode only) MPB3021AT: X‘00407496’

 

X‘0060AB30’

 

MPB3032AT: X‘0060AB30’

 

X‘0080E92C’

 

MPB3043AT: X‘0080E92C’

 

X‘009C73C2’

 

MPB3052AT: X‘009C73C2’

 

X‘00C15DC2’

 

MPB3064AT: X‘00C15DC2’

62

X‘0000’

Retired

 

63

X‘xx07’

Multiword DMA transfer mode *9

 

64

X‘0003’

Advance PIO transfer mode support status *10

65

X‘0078’

Minimum multiword DMA transfer cycle time per word : 120 [ns]

66

X‘0078’

Manufacturer's recommended DMA transfer cycle time : 120 [ns]

67

X‘00F0’

Minimum PIO transfer cycle time without flow control : 240 [ns]

68

X‘0078’

Minimum PIO transfer cycle time with IORDY flow control : 120 [ns]

69-79

X‘00’

Reserved

 

80

X‘000E’

Major version number *11

 

81

X‘0000’

Minor version number (not reported)

 

82

X‘0009’

Support of command sets *12

 

83

X‘4000’

Support of command sets (fixed)

 

84-87

X‘00’

Reserved

 

88

X‘xx07’

Ultra DMA modes *13

 

5 - 30