Table 1.3 Current and power dissipation
Mode of  | 
  | Typical RMS current (*1) [mA]  | 
  | Typical Power (*2) [watts]  | ||||
Operation  | 
  | 
  | 
  | 
  | 
  | |||
  | +12 V  | 
  | 
  | +5 V  | 
  | 
  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | ||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
Model  | MPB  | MPB  | MPB  | 
  | All Models  | MPB  | MPB  | MPB  | 
  | 3021AT  | 3032AT  | 3052AT  | 
  | 
  | 3021AT  | 3032AT  | 3052AT  | 
  | 
  | MPB  | MPB  | 
  | 
  | 
  | MPB  | MPB  | 
  | 
  | 3043AT  | 3064AT  | 
  | 
  | 
  | 3043AT  | 3064AT  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
Spin up  | 
  | 1300  | 
  | 
  | 460  | 
  | 17.9  | 
  | 
  | 
  | 1500 peak  | 
  | 
  | 600 peak  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
Idle (Ready)  | 115  | 140  | 185  | 
  | 460  | 3.68  | 3.98  | 4.52  | 
(*3)  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
R/W (On Track)  | 125  | 150  | 200  | 
  | 510  | 4.05  | 4.35  | 4.95  | 
(*4)  | 
  | |||||||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
Seek (Random)  | 335  | 360  | 410  | 
  | 510  | 6.57  | 6.87  | 7.47  | 
(*5)  | 
  | |||||||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
Standby  | 
  | 4  | 
  | 
  | 155  | 
  | 0.82  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
Sleep  | 
  | 4  | 
  | 
  | 110  | 
  | 0.60  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
*1 Current is typical rms except for spin up.
*2 Power requirements reflect nominal values for +12V and +5V power.
*3 Idle mode is in effect when the drive is not reading, writing, seeking, or executing any commands. A portion of the R/W circuitry is powered down, the spindle motor is up to speed and the Drive ready condition exists.
*4 R/W mode is defined as 50% read operations and 50% write operations on a single physical track.
*5 Seek mode is defined as continuous random seek operations with minimum controller delay.