Fujitsu MPB3043AT, MPB3054AT, MPB3032AT, MPB3052AT 2 Execution example of READ MULTIPLE command

Models: MPB3043AT MPB3021AT MPB3052AT MPB3032AT MPB3054AT

1 180
Download 180 pages 25.81 Kb
Page 84
Image 84
Figure 5.2 Execution example of READ MULTIPLE command

Figure 5.2 shows an example of the execution of the READ MULTIPLE command.

Block count specified by SET MULTIPLE MODE command = 4 (number of sectors in a block)

READ MULTIPLE command specifies;

Number of requested sectors = 9 (Sector Count register = 9)

Number of sectors in incomplete block = remainder of 9/4 =1

Command Issue

Parameter

 

 

 

Write

Status read

Status read

Status read

Manual background~Manual background

BSY

DRDY

INTRQ

DRQ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sector

1

2

3

4

 

5

6

7

8

 

9

 

 

 

 

 

 

 

 

 

 

transferred

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Partial

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

block

 

 

 

 

Block

 

 

 

 

 

Block

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 5.2 Execution example of READ MULTIPLE command

At command issuance (I/O registers setting contents)

1F7H(CM)

1

1

0

0

0

1

0

0

 

 

 

 

 

 

 

1F6H(DH)

×

L

×

DV

 

Start head No. /LBA [MSB]

 

 

 

 

 

 

 

 

1F5H(CH)

 

Start cylinder No. [MSB]/ LBA

 

 

1F4H(CL)

 

Start cylinder No. [LSB] / LBA

 

 

1F3H(SN)

 

Start sector No.

 

 

/ LBA [LSB]

 

1F2H(SC)

 

 

Transfer sector count

 

 

1F1H(FR)

 

 

 

 

xx

 

 

 

At command completion (I/O registers contents to be read)

1F7H(ST)

 

 

 

Status information

 

 

 

 

 

 

 

 

1F6H(DH)

×

L

×

 

DV

 

End head No. /LBA [MSB]

 

 

 

 

 

 

1F5H(CH)

 

End cylinder No. [MSB] / LBA

1F4H(CL)

 

End cylinder No. [LSB] / LBA

1F3H(SN)

 

End sector No.

/ LBA [LSB]

1F2H(SC)

 

 

 

 

00H

 

1F1H(ER)

 

 

 

Error information

C141-E045-02EN

5 - 19