Fujitsu MPB3043AT, MPB3054AT, MPB3032AT, MPB3052AT, MPB3021AT 3 Command code and parameters 1 of

Models: MPB3043AT MPB3021AT MPB3052AT MPB3032AT MPB3054AT

1 180
Download 180 pages 25.81 Kb
Page 79
Image 79

5.3.1Command code and parameters

Table 5.3 lists the supported commands, command code and the registers that needed parameters are written.

Table 5.3 Command code and parameters (1 of 2)

Command name

 

 

Command code (Bit)

 

 

Parameters used

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

6

 

5

4

3

2

 

1

0

FR

SC

SN

CY

DH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

READ SECTOR(S)

0

0

 

1

0

0

0

 

0

R

N

Y

Y

Y

 

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

READ MULTIPLE

1

1

 

0

0

0

1

 

0

0

N

Y

Y

Y

 

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

READ DMA

1

1

 

0

0

1

0

 

0

R

N

Y

Y

Y

 

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

READ VERIFY SECTOR(S)

0

1

 

0

0

0

0

 

0

R

N

Y

Y

Y

 

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WRITE MULTIPLE

1

1

 

0

0

0

1

 

0

1

N

Y

Y

Y

 

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WRITE DMA

1

1

 

0

0

1

0

 

1

R

N

Y

Y

Y

 

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WRITE VERIFY

0

0

 

1

1

1

1

 

0

0

N

Y

Y

Y

 

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WRITE SECTOR(S)

0

0

 

1

1

0

0

 

0

R

N

Y

Y

Y

 

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RECALIBRATE

0

0

 

0

1

X

X

 

X

X

N

N

N

N

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SEEK

0

1

 

1

1

X

X

 

X

X

N

N

Y

Y

 

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INITIALIZE DEVICE DIAGNOSTIC

1

0

 

0

1

0

0

 

0

1

N

Y

N

N

 

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IDENTIFY DEVICE

1

1

 

1

0

1

1

 

0

0

N

N

N

N

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IDENTIFY DEVICE DMA

1

1

 

1

0

1

1

 

1

0

N

N

N

N

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SET FEATURES

1

1

 

1

0

1

1

 

1

1

Y

N*

N

N

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SET MULTIPLE MODE

1

1

 

0

0

0

1

 

1

0

N

Y

N

N

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EXECUTE DEVICE DIAGNOSTIC

1

0

 

0

1

0

0

 

0

0

N

N

N

N

 

D*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FORMAT TRACK

0

1

 

0

1

0

0

 

0

0

N

N

Y*

Y

 

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

READ LONG

0

0

 

1

0

0

0

 

1

R

N

Y

Y

Y

 

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WRITE LONG

0

0

 

1

1

0

0

 

1

R

N

Y

Y

Y

 

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

READ BUFFER

1

1

 

1

0

0

1

 

0

0

N

N

N

N

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WRITE BUFFER

1

1

 

1

0

1

0

 

0

0

N

N

N

N

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IDLE

1

0

 

0

1

0

1

 

1

1

N

Y

N

N

 

D

 

1

1

 

1

0

0

0

 

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IDLE IMMEDIATE

1

0

 

0

1

0

1

 

0

1

N

N

N

N

 

D

 

1

1

 

1

0

0

0

 

0

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STANDBY

1

0

 

0

1

0

1

 

1

0

N

Y

N

N

 

D

 

1

1

 

1

0

0

0

 

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5 - 14

C141-E045-02EN

Page 79
Image 79
Fujitsu MPB3043AT, MPB3054AT, MPB3032AT, MPB3052AT, MPB3021AT manual 3 Command code and parameters 1 of