Hitachi HTS543225L9A300 manual 14.17Read Log Ext2Fh, Content, Feature set, Type, address

Models: HTS543225L9A300 HTS543232L9A300 HTS543216L9A300 HTS543216L9SA00 HTS543212L9A300 HTS543280L9SA00

1 177
Download 177 pages 46.29 Kb
Page 110
Image 110
14.17Read Log Ext(2Fh)
Sector Count Current
Sector Count Previous LBA Low Current LBA Mid Current LBA Mid Previous

5K320 SATA OEM Specification

14.17Read Log Ext(2Fh)

Command Block Output Registers

 

 

 

 

 

 

Command Block Input Registers

 

 

 

 

 

Register

 

 

7

6

5

4

3

2

1

0

Register

 

 

7

6

5

4

3

2

1

0

Data Low

 

 

-

-

-

-

-

-

-

-

Data Low

 

 

-

-

-

-

-

-

-

-

Data High

 

 

-

-

-

-

-

-

-

-

Data High

 

 

-

-

-

-

-

-

-

-

Feature

 

Current

-

-

-

-

-

-

-

R-

Error

 

 

 

 

 

...See Below...

 

 

 

 

Previous

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

Sector Count

Current

V

V

V

V

V

V

V

V

Sector Count

HOB=0 - - - -

-

-

-

-

 

 

Previous

V

V

V

V

V

V

V

V

 

 

HOB=1 - - - -

-

-

-

-

LBA Low

Current

V

V

V

V

V

V

V

V

LBA Low

HOB=0 - - - -

-

-

-

-

 

 

Previous

-

-

-

-

-

-

-

-

 

 

HOB=1 - - - -

-

-

-

-

LBA Mid

Current

V

V

V

V

V

V

V

V

LBA Mid

HOB=0 - - - -

-

-

-

-

 

 

Previous

V

V

V

V

V

V

V

V

 

 

HOB=1 - - - -

-

-

-

-

LBA High

Current

-

-

-

-

-

-

-

-

LBA High

HOB=0 - - - -

-

-

-

-

 

 

Previous

-

-

-

-

-

-

-

-

 

 

HOB=1

-

-

-

-

-

-

-

-

Device

 

 

 

-

-

-

-

-

-

-

-

Device

 

 

-

-

-

-

-

-

-

-

Command

 

 

0

0

1

0

1

1

1

1

Status

 

 

 

 

...See Below...

 

 

 

 

 

Error Register

 

 

 

 

 

 

 

 

 

Status Register

 

 

 

 

 

7

6

5

4

3

 

2

 

1

 

0

 

7

6

5

4

 

3

 

2

 

1

 

0

CRC

UNC

0

IDN

0

ABT

T0N

AMN

 

BSY

RDY

DF

DSC

DRQ

COR

IDX

ERR

V

V

0

V

0

 

V

 

0

 

0

 

0

V

0

V

 

-

 

0

 

0

 

V

Table 72 Read Log Ext Command (2Fh)

This command returns the specified log to the host. The device shall interrupt for each DRQ block transferred.

Output Parameters To The Device

RPhy Event Counter Reset bit. When Log address is 11h (Phy Event Counter) and this bit is set to 1, all Phy Event Counter values are reset to 0 after sending the current counter valules.

The number of sectors to be read from the specified log low order, bits (7:0). The log transferred by the drive shall start at the sector in the specified log at the specified offset, regardless of the sector count requested.

The number of sectors to be read from the specified log high orders, bits (15:8). The log to be returned as described in the following table.

The first sector of the log to be read low order, bits (7:0). The first sector of the log to be read high order, bits (15:8).

 

 

 

 

Log

Content

Feature set

Type

address

 

 

 

 

00h

Log directory

N/A

error

Read Only

03h

Extended Comprehensive SMART

SMART

Read Only

07h

error log

logging

 

Read Only

Extended SMART self-test log

SMART self-test

10h

Command Error

Native

Command

Read Only

11h

Phy Event Counter

Queuing

 

Read Only

Phy Event Counter

80h-9Fh

Host vendor specific

SMART

 

Read/Wri

 

 

 

 

te

Table 73 Log address definition

 

 

 

110

Page 110
Image 110
Hitachi HTS543225L9A300, HTS543232L9A300, HTS543280L9SA00 manual 14.17Read Log Ext2Fh, Content, Feature set, Type, address