Hitachi HTS543216L9A300, HTS543232L9A300, HTS543280L9SA00 manual 14.19Read Multiple Ext 29h

Models: HTS543225L9A300 HTS543232L9A300 HTS543216L9A300 HTS543216L9SA00 HTS543212L9A300 HTS543280L9SA00

1 177
Download 177 pages 46.29 Kb
Page 119
Image 119
14.19Read Multiple Ext (29h)

5K320 SATA OEM Specification

14.19Read Multiple Ext (29h)

 

Command Block Output Registers

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Command Block Input Registers

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Register

 

 

 

 

 

7

 

 

6

 

 

5

 

 

 

4

 

 

3

 

 

2

 

 

 

1

 

0

 

 

Register

 

 

 

7

 

 

 

6

 

5

 

 

 

4

3

 

 

 

2

 

1

 

 

 

0

 

Data Low

 

 

 

 

 

-

 

 

-

 

 

-

 

 

 

-

 

 

-

 

 

-

 

 

 

-

 

-

 

 

Data Low

 

 

 

-

 

 

 

-

 

-

 

 

 

-

-

 

 

 

-

 

-

 

 

 

-

 

Data High

 

 

 

 

 

-

 

 

-

 

 

-

 

 

 

-

 

 

-

 

 

-

 

 

 

-

 

-

 

 

Data High

 

 

 

-

 

 

 

-

 

-

 

 

 

-

-

 

 

 

-

 

-

 

 

 

-

 

Feature

 

 

Current

 

-

 

 

-

 

 

-

 

 

 

-

 

 

-

 

 

-

 

 

 

-

 

-

 

 

Error

 

 

 

 

 

 

 

 

 

 

 

...See Below...

 

 

 

 

 

 

 

 

 

 

Previous

 

-

 

 

-

 

 

-

 

 

 

-

 

 

-

 

 

-

 

 

 

-

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sector Count

Current

 

V

 

 

 

V

 

 

V

 

 

 

V

 

 

V

 

 

V

 

 

 

V

 

V

 

 

Sector Count

 

HOB=0

-

 

-

 

-

 

-

-

 

 

-

 

-

 

 

-

 

 

 

 

 

Previous

 

V

 

 

 

V

 

 

V

 

 

 

V

 

 

V

 

 

V

 

 

 

V

 

V

 

 

 

 

 

 

 

HOB=1

-

 

 

-

 

-

 

 

-

-

 

 

 

-

 

-

 

 

 

-

 

LBA Low

Current

 

V

 

 

 

V

 

 

V

 

 

 

V

 

 

V

 

 

V

 

 

 

V

 

V

 

 

LBA Low

 

HOB=0

V

 

 

V

 

V

 

 

V

V

 

 

V

 

V

 

 

V

 

 

 

 

 

Previous

 

V

 

 

 

V

 

 

V

 

 

 

V

 

 

V

 

 

V

 

 

 

V

 

V

 

 

 

 

 

 

 

HOB=1

V

 

 

V

 

V

 

 

V

V

 

 

V

 

V

 

 

V

 

LBA Mid

Current

 

V

 

 

 

V

 

 

V

 

 

 

V

 

 

V

 

 

V

 

 

 

V

 

V

 

 

LBA Mid

 

HOB=0

V

 

 

V

 

V

 

 

V

V

 

 

V

 

V

 

 

V

 

 

 

 

 

Previous

 

V

 

 

 

V

 

 

V

 

 

 

V

 

 

V

 

 

V

 

 

 

V

 

V

 

 

 

 

 

 

 

HOB=1

V

 

 

V

 

V

 

 

V

V

 

 

V

 

V

 

 

V

 

LBA High

Current

 

V

 

 

 

V

 

 

V

 

 

 

V

 

 

V

 

 

V

 

 

 

V

 

V

 

 

LBA High

 

HOB=0

V

 

 

V

 

V

 

 

V

V

 

 

V

 

V

 

 

V

 

 

 

 

 

Previous

 

V

 

 

 

V

 

 

V

 

 

 

V

 

 

V

 

 

V

 

 

 

V

 

V

 

 

 

 

 

 

 

HOB=1

V

 

 

 

V

 

V

 

 

 

V

V

 

 

 

V

 

V

 

 

 

V

 

Device

 

 

 

 

 

 

 

-

 

 

1

 

 

-

 

 

 

-

 

 

-

 

 

-

 

 

 

-

 

-

 

 

Device

 

 

 

-

 

 

 

-

 

-

 

 

 

-

-

 

 

 

-

 

-

 

 

 

-

 

Command

 

 

 

 

0

0

1

0

1

 

0

 

 

0

 

1

 

 

Status

 

 

 

 

 

 

 

 

 

...See Below...

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Error Register

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Status Register

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

6

 

5

 

4

 

3

 

 

 

 

2

 

 

 

 

1

 

 

 

0

 

 

7

 

6

 

5

 

4

 

3

 

 

2

 

1

 

 

0

 

CRC

 

UNC

 

0

 

IDN

 

0

 

 

 

ABT

T0N

 

 

AMN

 

 

BSY

 

RDY

 

DF

DSC

DRQ

 

COR

IDX

ERR

 

0

 

V

 

0

 

V

 

0

 

 

 

 

 

V

 

0

 

 

 

0

 

 

0

 

V

 

0

 

V

 

-

 

 

0

 

0

 

 

V

 

Table 85 Read Multiple Ext Command (29h)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output Parameters To The Device

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sector Count Current

The number of sectors to be transferred low order, bits (7:0).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sector Count Previous

The number of sectors to be transferred high order, bits (15:8). If 0000h in the Sector

LBA Low Current

 

 

Count register is specified, then 65,536 sectors will be transferred.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LBA (7:0)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LBA Low Previous

 

 

LBA (31:24)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LBA Mid Current

 

 

LBA (15:8)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LBA Mid Previous

 

 

LBA (39:32)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LBA High Current

 

 

LBA (23:16)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LBA High Previous

 

 

LBA (47:40)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input Parameters From The Device

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LBA Low (HOB=0)

 

 

LBA (7:0) of the address of the first unrecoverable error.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LBA Low (HOB=1)

 

 

LBA (31:24)of the address of the first unrecoverable error.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LBA Mid (HOB=0)

 

 

LBA (15:8)of the address of the first unrecoverable error.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LBA Mid (HOB=1)

 

 

LBA (39:32)of the address of the first unrecoverable error.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LBA High (HOB=0)

 

 

LBA (23:16)of the address of the first unrecoverable error.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LBA High (HOB=1)

 

 

LBA (47:40)of the address of the first unrecoverable error.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

119

Page 119
Image 119
Hitachi HTS543216L9A300, HTS543232L9A300, HTS543280L9SA00, HTS543225L9A300, HTS543216L9SA00 manual 14.19Read Multiple Ext 29h