5K320 SATA OEM Specification

14.25Read Verify Sector(s) Ext (42h)

Command Block Output Registers

 

 

 

 

 

 

Command Block Input Registers

 

 

 

 

 

Register

 

 

7

6

5

4

3

2

1

0

Register

 

7

6

5

4

3

2

1

0

Data Low

 

 

-

-

-

-

-

-

-

-

Data Low

 

-

-

-

-

-

-

-

-

Data High

 

 

-

-

-

-

-

-

-

-

Data High

 

-

-

-

-

-

-

-

-

Feature

 

Current

-

-

-

-

-

-

-

-

Error

 

 

 

 

...See Below...

 

 

 

 

Previous

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

Sector Count

Current

V

V

V

V

V

V

V

V

Sector Count

HOB=0 - - - -

-

-

-

-

 

 

Previous

V

V

V

V

V

V

V

V

 

 

HOB=1 - - - -

-

-

-

-

LBA Low

Current

V

V

V

V

V

V

V

V

LBA Low

HOB=0 V V V V V V V V

 

 

Previous

V

V

V

V

V

V

V

V

 

 

HOB=1 V V V V V V V V

LBA Mid

Current

V

V

V

V

V

V

V

V

LBA Mid

HOB=0 V V V V V V V V

 

 

Previous

V

V

V

V

V

V

V

V

 

 

HOB=1 V V V V V V V V

LBA High

Current

V

V

V

V

V

V

V

V

LBA High

HOB=0 V V V V V V V V

 

 

Previous

V

V

V

V

V

V

V

V

 

 

HOB=1 V

V

V

V

V

V

V

V

Device

 

 

 

-

1

-

-

-

-

-

-

Device

 

-

-

-

-

-

-

-

-

Command

 

 

0

0

1

0

0

0

1

0

Status

 

 

 

...See Below...

 

 

 

 

 

Error Register

 

 

 

 

 

 

 

 

 

Status Register

 

 

 

 

 

7

6

5

4

3

 

2

 

1

 

0

 

7

6

5

4

3

 

2

 

1

 

0

CRC

UNC

0

IDN

0

ABT

T0N

AMN

 

BSY

RDY

DF

DSC DRQ

COR

IDX

ERR

0

V

0

V

0

 

V

 

0

 

0

 

0

V

0

V

-

 

0

 

0

 

V

Table 91 Read Verify Sector(s) Ext Command (42h)

The Read Verify Sector(s) Ext verifies one or more sectors on the device. No data is transferred to the host.

The difference between the Read Sector(s) Ext command and the Read Verify Sector(s) Ext command is whether the data is transferred to the host or not.

If an uncorrectable error occurs, the Read Verify Sector(s) Ext will be terminated at the failing sector.

Output Parameters To The Device

Sector Count Current

The number of sectors to be transferred low order, bits (7:0).

Sector Count Previous

The number of sectors to be transferred high order, bits (15:8). If 0000h in the Sector

LBA Low Current

Count register is specified, then 65,536 sectors will be verified.

LBA (7:0)

LBA Low Previous

LBA (31:24)

LBA Mid Current

LBA (15:8)

LBA Mid Previous

LBA (39:32)

LBA High Current

LBA (23:16)

LBA High Previous

LBA (47:40)

Input Parameters From The Device

LBA Low (HOB=0)

LBA (7:0) of the address of the first unrecoverable error.

LBA Low (HOB=1)

LBA (31:24)of the address of the first unrecoverable error.

LBA Mid (HOB=0)

LBA (15:8)of the address of the first unrecoverable error.

LBA Mid (HOB=1)

LBA (39:32)of the address of the first unrecoverable error.

LBA High (HOB=0)

LBA (23:16)of the address of the first unrecoverable error.

LBA High (HOB=1)

LBA (47:40)of the address of the first unrecoverable error.

125

Page 125
Image 125
Hitachi HTS543216L9A300, HTS543232L9A300, HTS543280L9SA00 Read Verify Sectors Ext 42h, Read Verify Sectors Ext Command 42h