14.7 Format Track (50h: Vendor Specific)

5K320 SATA OEM Specification

14.7 Format Track (50h: Vendor Specific)

Command Block Output Registers

 

 

 

 

 

 

Command Block Input Registers

 

 

 

 

 

 

 

Register

7

6

5

4

3

2

1

0

Register

7

6

5

4

3

2

1

0

Data

-

-

-

-

-

-

-

-

Data

-

-

-

-

-

-

-

-

Feature

-

-

-

-

-

-

-

-

Error

 

 

...See Below...

 

 

Sector Count

-

-

-

-

-

-

-

-

Sector Count

-

-

-

-

-

-

-

-

LBA Low

V V V V V V V V

LBA Low

V V V V V V

V V

LBA Mid

V V V V V V V V

LBA Mid

V V V V V V

V V

LBA High

V V V V V V V V

LBA High

V V V V V V

V V

Device

-

L

-

- H H H H

Device

-

-

-

-

H

H

H

H

Command

0

1

0

1

0

0

0

0

Status

 

 

...See Below...

 

 

Error Register

7

6

5

4

3

2

1

0

CRC

UNC

0

IDN

0

ABT

T0N

AM

 

 

 

 

 

 

 

N

00 0  0  V  0  V  0  0 Table 52 Format Track Command (50h)Manual background 0 Manual backgroundManual background 0 Manual backgroundManual background V Manual backgroundManual background 0 Manual backgroundManual background V Manual backgroundManual background 0 Manual backgroundManual background 0 Table 52 Format Track Command (50h)

Status Register

7

6

5

4

3

2

1

0

BSY

RDY

DF

DSC

DRQ

COR

IDX

ERR

0

V

0

V

-

0

0

V

The Format Track command formats a single logical track on the device. Each good sector of data on the track will be initialized to zero with write operation. At this time, whether the sector of data is initialized correctly is not verified with read operation. Any data previously stored on the track will be lost.

Output Parameters To The Device

LBA Low

In LBA mode, this register specifies LBA address bits 0 - 7 to be formatted. (L=1)

LBA High/Mid

The cylinder number of the track to be formatted. (L=0)

 

In LBA mode, this register specifies LBA address bits 8 - 15 (Mid), 16 - 23 (High) to be

H

formatted. (L=1)

The head number of the track to be formatted. (L=0)

 

In LBA mode, this register specifies LBA address bits 24 - 27 to be formatted. (L=1)

Input Parameters From The Device

LBA Low

In LBA mode, this register specifies current LBA address bits 0-7. (L=1)

LBA High/Mid

In LBA mode, this register specifies current LBA address bits 8 - 15 (Mid), 16 - 23 (High)

H

In LBA mode, this register specifies current LBA address bits 24 - 27. (L=1)

In LBA mode, this command formats a single logical track including the specified LBA.