5K320 SATA OEM Specification

14.48Write Log Ext (3Fh)

Command Block Output Registers

 

 

 

 

 

 

Command Block Input Registers

 

 

 

 

 

Register

 

 

7

6

5

4

3

2

1

0

Register

 

 

7

6

5

4

3

2

1

0

Data Low

 

 

-

-

-

-

-

-

-

-

Data Low

 

 

-

-

-

-

-

-

-

-

Data High

 

 

-

-

-

-

-

-

-

-

Data High

 

 

-

-

-

-

-

-

-

-

Feature

 

Current

-

-

-

-

-

-

-

-

Error

 

 

 

 

 

...See Below...

 

 

 

 

Previous

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

Sector Count

Current

V

V

V

V

V

V

V

V

Sector Count

HOB=0 - - - -

-

-

-

-

 

 

Previous

V

V

V

V

V

V

V

V

 

 

HOB=1 - - - -

-

-

-

-

LBA Low

Current

V

V

V

V

V

V

V

V

LBA Low

HOB=0 - - - -

-

-

-

-

 

 

Previous

-

-

-

-

-

-

-

-

 

 

HOB=1 - - - -

-

-

-

-

LBA Mid

Current

V

V

V

V

V

V

V

V

LBA Mid

HOB=0 - - - -

-

-

-

-

 

 

Previous

V

V

V

V

V

V

V

V

 

 

HOB=1 - - - -

-

-

-

-

LBA High

Current

-

-

-

-

-

-

-

-

LBA High

HOB=0 - - - -

-

-

-

-

 

 

Previous

-

-

-

-

-

-

-

-

 

 

HOB=1

-

-

-

-

-

-

-

-

Device

 

 

 

-

-

-

-

-

-

-

-

Device

 

 

-

-

-

-

-

-

-

-

Command

 

 

0

0

1

1

1

1

1

1

Status

 

 

 

 

...See Below...

 

 

 

 

 

Error Register

 

 

 

 

 

 

 

 

 

Status Register

 

 

 

 

 

7

6

5

4

3

 

2

 

1

 

0

 

7

6

5

4

 

3

 

2

 

1

 

0

CRC

UNC

0

IDN

0

ABT

T0N

AMN

 

BSY

RDY

DF

DSC

DRQ

COR

IDX

ERR

V

V

0

V

0

 

V

 

0

 

0

 

0

V

0

V

 

-

 

0

 

0

 

V

Table 132 Write Log Ext Command

This command writes a specified number of 512 byte data sectors to the specific log. The device shall interrupt for each DRQ block transferred.

Output Parameters To The Device

Sector Count Current The number of sectors to be written to the specified log low order, bits (7:0).

Sector Count Previous The number of sectors to be written to the specified log high orders, bits (15:8). If the number of sectors is greater than the number indicated in the Log directory, which is available in Log number zero, the device shall return command aborted. The log transferred to the device shall be stored by the device starting at the first sector in the specified log.

Sector Number Current The log to be written as described in Table 111 Log sector addresses definition. If the host attempts to write to a read only log address, the device shall return command aborted.

Cylinder Low Current The first sector of the log to be written low order, bits (7:0).

Cylinder Low Previous The first sector of the log to be written high order, bits (15:8)

If the feature set associated with the log specified in the Sector Number register is not supported or enabled, or if the values in the Sector Count, Sector Number or Cylinder Low registers are invalid, the device shall return command aborted. If the host attempts to write to a read only log address, the device shall return command aborted.