14.17.5Phy Event Counter

5K320 SATA OEM Specification

The Data Structure Checksum (Byte 511) contains the 2’s complement of the sum of the first 511 bytes in the data structure. The sum of all 512 bytes of the data structure will be zero when the checksum is correct.

14.17.5Phy Event Counter

Phy Event Counters are a feature to obtain more information about Phy level events that occur on the interface. The counter values are not retained across power cycles. The counter values are preserved across COMRESET and software resets.

14.17.5.1Counter Reset Mechanisms

There are 2 mechanisms by which the host can explicitly cause the Phy counters to be reset. The first mechanism is to issue a BIST Activate FIS to the drive. The second mechanism uses the Read Log Ext command. When the drive receives a Read Log Ext command for log page 11h and bit 0 in Feature register is set to one, the drive returns the current counter values for the command and then resets all Phy event counter values.

14.17.5.2Counter Identifiers

Each counter begins with a 16-bit identifier. The following table defines the counter value for each identifier.

For all counter descriptions, “transmitted” refers to items sent by the drive to the host and “received” refers to items received by the drive from the host.

Bits 14:12 of the counter identifier convey the number of significant bits that counter uses. All counter values consumes a multiple of 16-bits. The valid values for bit 14:12 and the corresponding counter size are:

1h

16-bit counter

2h

32-bit counter

3h

48-bit counter

4h

64-bit counter

 

 

Identifier

Description

(Bits 11:0)

000h

No counter value; marks end of counters in the page

001h

Command failed due to ICRC error

009h

Transfer from drive PhyRdy to drive PhyNRdy

00Ah

Signature D2H register FISes sent due to a COMRESET

00Bh

CRC errors within the FIS (received)

00Dh

Non-CRC errors within the FIS (received)

Table 82 Phy Event Counter Identifier