5K320 SATA OEM Specification

 

 

 

 

 

 

 

 

 

 

 

(Hex)

 

 

 

(S.M.A.R.T Function)

 

 

 

 

 

 

S.M.A.R.T. Read Attribute Values

B0

 

D0

 

 

 

S.M.A.R.T. Read Attribute Thresholds

B0

 

D1

 

 

 

S.M.A.R.T. Enable/Disable Attribute Autosave

B0

 

D2

 

 

 

S.M.A.R.T. Save Attribute Values

B0

 

D3

 

 

 

S.M.A.R.T. Execute Off-line Immediate

B0

 

D4

 

 

 

S.M.A.R.T. Read Log Sector

B0

 

D5

 

 

 

S.M.A.R.T. Write Log Sector

B0

 

D6

 

 

 

S.M.A.R.T. Enable Operations

B0

 

D8

 

 

 

S.M.A.R.T. Disable Operations

B0

 

D9

 

 

 

S.M.A.R.T. Return Status

B0

 

DA

 

 

 

S.M.A.R.T. Enable/Disable Automatic Off-line

B0

 

DB

 

 

 

(Set Features)

 

 

 

 

 

 

Enable Write Cache

EF

 

02

 

 

 

Set Transfer Mode

EF

 

03

 

 

 

Enable Advanced Power Management feature

EF

 

05

 

 

 

Enable Power-Up in Standby feature

EF

 

06

 

 

 

Power-Up in Standby feature device Spin-Up

EF

 

07

 

 

 

Enable use of Serial ATA feature

EF

 

10

 

 

 

Disable read look-ahead feature

EF

 

55

 

 

 

Disable reverting to power on defaults

EF

 

66

 

 

 

Disable write cache

EF

 

82

 

 

 

Disable Advanced Power Management feature

EF

 

85

 

 

 

Disable Power-Up in Standby feature

EF

 

86

 

 

 

Disable use of Serial ATA feature

EF

 

90

 

 

 

Enable read look-ahead feature

EF

 

AA

 

 

 

Enable reverting to power on defaults

EF

 

CC

 

 

 

(Set Max security extension)

 

 

 

 

 

 

Set Max Set Password

F9

 

01

 

 

 

Set Max Lock

F9

 

02

 

 

 

Set Max Unlock

F9

 

03

 

 

 

Set Max Freeze Lock

F9

 

04

 

 

 

(Device Configuration Overlay)

 

 

 

 

 

 

Device Configuration Restore

B1

 

C0

 

 

 

Device Configuration Freeze Lock

B1

 

C1

 

 

 

Device Configuration Identify

B1

 

C2

 

 

 

Device Configuration Set

B1

 

C3

 

Table 42 Command Set (Subcommand)

“Table 40 Command set” on Page 75 shows the commands that are supported by the device. “ Table 42 Command Set (Subcommand)” on Page 77 shows the sub-commands that are supported by each command or feature.

The following symbols are used in the command descriptions:

Output Registers

0Indicates that the bit must be set to 0.

1Indicates that the bit must be set to 1.

HHead number. Indicates that the head number part of the Device Register is an output parameter and should

be specified.

LLBA mode. Indicates the addressing mode. Zero specifies CHS mode and one does LBA addressing mode. R Retry. Original meaning is already obsolete, there is no difference between 0 and 1. (Using 0 is

recommended for future compatibility.)

B Option Bit. Indicates that the Option Bit of the Sector Count Register should be specified. (This bit is used by

77

Page 77
Image 77