Hitachi HTS543232L9A300, HTS543280L9SA00 manual 12.10.2Set Max security extension commands

Models: HTS543225L9A300 HTS543232L9A300 HTS543216L9A300 HTS543216L9SA00 HTS543212L9A300 HTS543280L9SA00

1 177
Download 177 pages 46.29 Kb
Page 66
Image 66
12.10.2Set Max security extension commands

5K320 SATA OEM Specification

12.10.2Set Max security extension commands

The Set Max Set Password command allows the host to define the password to be used during the current power on cycle. This password is not related to the password used for the Security Mode Feature set. When the password is set the device is in the Set Max Unlocked mode.

This command requests a transfer of a single sector of data from the host. The table shown below defines the content of this sector of information. The password is retained by the device until the next power cycle. When the device accepts this command the device is in Set Max Unlocked mode.

Word

Content

0

Reserved

1-16

Password (32 bytes)

17-255

Reserved

Table 37 Set Max Set Password data content

The Set Max Lock command allows the host to disable the Set Max commands (except Set Max Unlock and Set Max Freeze Lock) until the next power cycle or the issuance and acceptance of the Set Max Unlock command. When this command is accepted the device is in the Set Max Locked mode.

The Set Max Unlock command changes the device from the Set Max Locked mode to the Set Max Unlocked mode.

This command requests a transfer of a single sector of data from the host. The Table shown above defines the content of this sector of information. The password supplied in the sector of data transferred is compared with the stored Set Max password. If the password compare fails, then the device returns command aborted and decrements the unlock counter. On the acceptance of the Set Max Lock command, this counter is set to a value of five and is decremented for each password mismatch when Set Max Unlock is issued and the device is locked. When this counter reaches zero, then the Set Max Unlock command returns command aborted until a power cycle.

The Set Max Freeze Lock command allows the host to disable the SET Max commands (including Set Max Unlock) until the next power cycle. When this command is accepted the device is in the Set Max Frozen mode.

The password, the Set Max security mode and the unlock counter don’t persist over a power cycle but does persist over a COMRESET or software reset.

Note that If this command is immediately preceded by a Read Native Max Address command regardless of Feature register value, it shall be interpreted as a Set Max Address command.

Figure 8 Set Max security mode transition

- 66 -

Page 66
Image 66
Hitachi HTS543232L9A300, HTS543280L9SA00 12.10.2Set Max security extension commands, Set Max Set Password data content