Hitachi HTS543216L9SA00 manual 14.37Set Max Address Ext 37h, Set Max Address Ext Command 37h

Models: HTS543225L9A300 HTS543232L9A300 HTS543216L9A300 HTS543216L9SA00 HTS543212L9A300 HTS543280L9SA00

1 177
Download 177 pages 46.29 Kb
Page 141
Image 141
14.37Set Max Address Ext (37h)

5K320 SATA OEM Specification

14.37Set Max Address Ext (37h)

Command Block Output Registers

 

 

 

 

 

 

Command Block Input Registers

 

 

 

 

 

Register

 

 

7

6

5

4

3

2

1

0

Register

 

7

6

5

4

3

2

1

0

Data Low

 

 

-

-

-

-

-

-

-

-

Data Low

 

-

-

-

-

-

-

-

-

Data High

 

 

-

-

-

-

-

-

-

-

Data High

 

-

-

-

-

-

-

-

-

Feature

 

Current

-

-

-

-

-

-

-

-

Error

 

 

 

 

...See Below...

 

 

 

 

Previous

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

Sector Count

Current

-

-

-

-

-

-

-

B

Sector Count

HOB=0 - - - -

-

-

-

-

 

 

Previous

-

-

-

-

-

-

-

-

 

 

HOB=1 - - - -

-

-

-

-

LBA Low

Current

V

V

V

V

V

V

V

V

LBA Low

HOB=0 V V V V V V V V

 

 

Previous

V

V

V

V

V

V

V

V

 

 

HOB=1 V V V V V V V V

LBA Mid

Current

V

V

V

V

V

V

V

V

LBA Mid

HOB=0 V V V V V V V V

 

 

Previous

V

V

V

V

V

V

V

V

 

 

HOB=1 V V V V V V V V

LBA High

Current

V

V

V

V

V

V

V

V

LBA High

HOB=0 V V V V V V V V

 

 

Previous

V

V

V

V

V

V

V

V

 

 

HOB=1 V

V

V

V

V

V

V

V

Device

 

 

 

-

1

-

-

-

-

-

-

Device

 

-

-

-

-

-

-

-

-

Command

 

 

0

0

1

1

0

1

1

1

Status

 

 

 

...See Below...

 

 

 

 

 

Error Register

 

 

 

 

 

 

 

 

 

Status Register

 

 

 

 

 

7

6

5

4

3

 

2

 

1

 

0

 

7

6

5

4

3

 

2

 

1

 

0

CRC

UNC

0

IDN

0

ABT

T0N

AMN

 

BSY

RDY

DF

DSC DRQ

COR

IDX

ERR

0

0

0

0

0

 

V

 

0

 

0

 

0

V

0

-

-

 

0

 

0

 

V

Table 107 Set Max Address Ext Command (37h)

This command is immediately preceded by a Read Native Max Address Ext command.

This command overwrites the maximum number of Address of HDD in a range of actual device capacity. Once device receives this command, all accesses beyond that Address are rejected with setting ABORT bit in status register.

When the address requested is greater than 268,435,455, words (103:100) shall be modified to reflect the requested value, but words (61:60) shall not modified. When the address requested is equal to or less than 268,435,455, words (103:100) shall be modified to reflect the requested value, and words (61:60) shall also be modified.

If this command is not supported, the maximum value to be set exceeds the capacity of the device, a host protected area has been established by a Set Max Address command, the command is not immediately preceded by a Read Native Max Address Ext command, or the device is in the Set Max Locked or Set Max Frozen state, the device shall return command aborted.

The device returns the command aborted for a second non-volatile Set Max Address Ext command until next power on.

Output Parameters To The Device

 

B

Option bit for selection whether nonvolatile or volatile. B=0 is volatile

 

condition. When B=1, Max Address which is set by Set Max Address

 

Ext command is preserved by POR. When B=0, Max Address which is

LBA Low Current

set by Set Max Address Ext command will be lost by POR.

Set Max LBA (7:0).

LBA Low Previous

Set Max LBA (31:24).

LBA Mid Current

Set Max LBA (15:8).

LBA Mid Previous

Set Max LBA (39:32).

LBA High Current

Set Max LBA (23:16).

LBA High Previous

Set Max LBA (47:40).

Input Parameters From The Device

 

LBA Low (HOB=0)

Set Max LBA (7:0).

141

Page 141
Image 141
Hitachi HTS543216L9SA00, HTS543232L9A300, HTS543280L9SA00 14.37Set Max Address Ext 37h, Set Max Address Ext Command 37h