5K320 SATA OEM Specification

The Extended SMART self-test log sector shall support 48-bit and 28-bit addressing. All 28-bit entries contained in the SMART self-test log sector shall also be included in the Comprehensive SMART self-test log sector with the 48-bit entries.

If the feature set associated with the log specified in the Sector Number register is not supported or enabled, or if the values in the Sector Count, Sector Number or Cylinder Low registers are invalid, the device shall return command aborted.

14.17.1General purpose Log Directory

The following table defines the 512 bytes that make up the General Purpose Log Directory.

Description

Bytes

Offset

General Purpose Logging Version

2

00h

Number of sectors in the log at log address 01h (7:0)

1

02h

Number of sectors in the log at log address 01h (15:8)

1

03h

Number of sectors in the log at log address 02h (7:0)

1

04h

Number of sectors in the log at log address 02h (15:8)

1

05h

...

1

100h

Number of sectors in the log at log address 80h (7:0)

Number of sectors in the log at log address 80h (15:8)

1

101h

...

1

1FEh

Number of sectors in the log at log address FFh (7:0)

Number of sectors in the log at log address FFh (15:8)

1

1FFh

 

512

 

Table 74 General purpose Log Directory

The value of the General Purpose Logging Version word shall be 0001h. A value of 0000h indicates that there is no General Purpose Log Directory.

The logs at log addresses 80-9Fh shall each be defined as 16 sectors long.

14.17.2Extended comprehensive SMART error log

The following table defines the format of each of the sectors that comprise the Extended Comprehensive SMART error log. Error log data structure shall not include errors attributed to the receipt of faulty commands such as command codes not implemented by the device or requests with invalid parameters or in valid addresses.