Furuno FS-5070 manual Test Call, 11-6

Models: FS-5070

1 219
Download 219 pages 18.3 Kb
Page 174
Image 174

11. MAINTENANCE & TROUBLESHOOTING

11.6Test Call

This function sends a test signal to a coast or ship station, over one of six distress and safety frequencies. For that reason, it should not be executed unnecessarily. You can prepare a test call beforehand (see Chapter 6) or at the moment you intend to send a test call. To send a prepared test call, see paragraph 6.5.4 for the procedure. When sending the test call at the moment, do the following.

1. Press the 2/DSC key.

Select Message

 

 

GENERAL

DISTRESS

 

 

INDIVIDUAL

 

RELAY AREA

 

 

PSTN MESSAGE

 

RELAY COAST

 

 

TEST MESSAGE

DISTRESS

 

 

GROUP MESSAGE

 

 

 

 

 

AREA MESSAGE

SPECIAL

 

 

POSITION

 

 

MMSI 123456789

UTC 01:53

 

 

POS 12 34.5678N

 

 

123 45.6789E

EPFS 01:54

2.Rotate the ENTER knob to choose TEST MESSAGE and then push the ENTER knob.

3.Push the ENTER knob to open the STATION ID window.

4.Rotate the ENTER knob to choose MANUAL or SELECT.

5.For SELECT, you can choose an ID from the message file list stored.

6.For MANUAL, using the numeric keys, key in the ID of the station ID (nine digits) where to send the call and then push the ENTER knob.

Compose msg.

MSG TYPE

STATION ID

PRIORITY

:TEST MESSAGE

*********

:SAFETY

DSC FREQ :

2187.5 kHz

GO TO VIEW

7.Push the ENTER knob to open the DSC FREQ menu. (Note that PRIORITY is automatically selected to SAFETY.)

Compose msg.

 

 

 

 

 

MSG TYPE

 

 

2187.5

 

 

4207.5

 

STATION ID

 

6312.0

 

PRIORITY

 

 

 

8414.5

 

 

 

12577.0

 

DSC FREQ

 

16804.5

 

GO TO VIEW

 

kHz

8.Rotate the ENTER knob to choose an appropriate frequency and then push the ENTER knob. The display changes as below.

11-6

Page 174
Image 174
Furuno FS-5070 manual Test Call, 11-6