FURUNO

NX-700A/B

4

ANTENNA UNIT

 

4.1

Antenna type

NX-7H: H-field antenna

4.2

Output impedance

50 ohms

4.3

Power supply

+7 V to +9 V (thru co-ax cable)

5

INTERFACE

 

5.1

Input data

IEC61162-1, -2

 

 

GGA, GLL, RMC, ZDA, NRQ, NMK, ACK, GNS, VHW, VTG, VBW

 

Output data

NRX, ALR

5.2

Alarm

Normal close, contact closure signal (floating, max. 80 mA, 50 V)

 

 

for SAR alert

6

POWER SUPPLY

 

 

6.1

NX-700A

12-24VDC:

1.5-0.8A

6.1

NX-700B

12-24VDC:

0.7-0.4A

7 ENVIRONMENTAL CONDITION

7.1Ambient temperature

 

Antenna unit

-25°C to +70°C

 

Receiver / Display unit

-15°C to +55°C

7.2

Relative humidity

95% at 40°C (without dew condensation)

7.3

Waterproofing

 

 

Antenna unit

IP66

 

Receiver / Display unit

IP20 (NX-700B: IP25 for front panel)

7.4

Vibration

- 2Hz to 5 Hz and up to 13.2 Hz with a deviation of ±1 mm ±10%

 

 

(7 m/s2 maximum acceleration at 13.2 Hz);

 

 

- above 13.2 Hz and up to 100 Hz with a constant maximum

 

 

acceleration of 7 m/s2 .

8

COATING COLOR

 

8.1

Display unit

N3.0

8.2

Receiver unit

N3.0

8.3

Antenna unit

N9.5

SP - 2