GEK-00029A 5000 Series Programmer’s Manual
169
DECLLG Loading Logo Sequence: A graphic image is downloaded and st ored
in printer memory.
General Command Syntax
DCS P1 P2 & t record ST
P1 specifies the logo file format. (must be 0)
P1 = 0 LG-series printer logo file format.
P2 lists the logos to be deleted.
P2 = 0 Delete all l ogos.
P2 = n Delete any logo with the same L ogo ID (n).
Record
The record includes the logo header and the graphic row records
used to print the image.
ID Length = One digit number (1 through 4) that defines the
length of the logo ID.
Logo ID = String of one to four numerals that identify the
logo.
Comment Length = One digit number (0 through 7) that
defines the length of the comment field.
Logo Length = A five digit number (00001 through 65535)
that defines the length of the logo record.
Row Records = R;S;N1;N2;…\
R = Height of the segment in mils.
S = Row starting color. ( 0=white, 1=black)
N1: N2 = Length of segment in mils.
\ = Row terminator.
Indeterminate Conditions
Logos can be loaded at any time except during another download
operation and during a form printing operation. When loaded, they
are available until they are replaced, deleted, or th e printer power is
turned off.
The start row color, defined within the Row Record, will switch with
each subsequent segment printed.
Decimal: 144 P1 59 P2 38 116 record 156
Hex: 90 P1H 3B P2H 26 74 record 9C
BASIC: CHR$(144);P1;CHR$(59);P2;”&t”;”record”;CHR$(156);
NOTE
The logo length includes all characters other than C0 control
characters (0 through 1F hex).