Programming

Portable Dryer Troubleshooting

 

 

 

Programming Instructions for EMCS Grain Dryers

1.Turn Control Power on dryer to off.

2.Locate programming jack (P7) on back of computer. (See page 13).

3.Plug the DB-9 jack of the programmer into the computer's jack.

4.Be sure that the rotary switch on the programmer is set to position 8.

5.Turn on Control Power to the dryer.

6.The four (4) lights on the programmer will come on, then three (3) will go out leaving the power light still on.

7.Push the start button on the programmer to start the transfer of Software.

8.The busy light will flash until the transfer process is complete.

9.When completed the pass light will flash indicating a successful transfer.

10.If the fail light flashes then check your connections and repeat the above process.

11.Turn Control Power on dryer to off and remove the cable.

12.Turn on the dryer and the opening screens should indicate the newer version of software.