Portable Dryer Troubleshooting

Wiring Reference

New Fenwal Board Wiring

The B. GND terminal is used to ground the burner and to complete the flame current signal circuit. This terminal is new for systems that used the older version of the Fenwal board. This terminal must be connected to the burner (chassis) ground not only to ensure the best, long term, stable flame signal, but also to ground the burner for

proper sparking.

The use of a burner ground terminal eliminates the problem of loss of flame sense signal due to a missing or loose neutral or ground (green) wire at the 120 VAC power source. The new board has been designed such that reversing the polarity of the 120 VAC line does not cause a loss of flame signal. Thus providing a more reliable flame signal along with a reduction of nuisance lockouts, due to its design and the use of the B. GND terminal.

L2

V2

(A) L1

GAS

VALVE

(B)V1

S1 H.V.

E2 E1

NEU.

120

VAC

H.V.

S1

HOT

B. GND

 

L1

BURNERV2 L2

V1

NC

BURNER

HOT

120

NEU. VAC

GAS

VALVE

Old version with Remote Flame Sense.

New version with Remote Sense using existing

 

spark and remote sense electrodes.

Note that terminal E2 on the old version has been replaced by terminal B.GND on the new board.

IGNITOR

Part No. HF-4624

Flame Safety Board

BURNER GROUND (B. GND)

FLAME ROD

39

Page 40
Image 40
GSI Outdoors PNEG-630 manual Ignitor