![](/images/new-backgrounds/1148393/148393175x1.webp)
Portable Dryer Troubleshooting | Competitor Wiring Reference |
Setting SCR Board Minimum Voltage
1.Switch the Moisture Control Switch back to the on position. This will put the meter roll rotation speed at the low setting.
2.Use a voltmeter set at the 20 volt DC range and probe terminal A+ with the red voltmeter probe and A- with the black voltmeter probe. Use a small screw driver and adjust the min set potentiom- eter until the voltage is 9 VDC.
The SCR board is now set and dryer is ready for normal operation at desired settings.
SCR Drive Board (Part No. D03-0104)
MIN
A+ A-
87