Portable Dryer Troubleshooting

Competitor Wiring Reference

Setting SCR Board Minimum Voltage

1.Switch the Moisture Control Switch back to the on position. This will put the meter roll rotation speed at the low setting.

2.Use a voltmeter set at the 20 volt DC range and probe terminal A+ with the red voltmeter probe and A- with the black voltmeter probe. Use a small screw driver and adjust the min set potentiom- eter until the voltage is 9 VDC.

The SCR board is now set and dryer is ready for normal operation at desired settings.

SCR Drive Board (Part No. D03-0104)

MIN

A+ A-

87

Page 88
Image 88
GSI Outdoors PNEG-630 manual SCR Drive Board Part No. D03-0104