Portable Dryer Troubleshooting | Wiring Reference |
1200 Fan Lower Control Box Interconnect Strip
J9-1
J9-3
L1
B1
B2
S1
S2
SCR2
|
| |||
LOAD | LINE |
|
|
|
| 5VB1 | |||
| EMI FILTER |
|
|
|
|
|
|
| |
| BLACK - 120 VAC |
| - OUTSIDE LIGHT | |
| BROWN - 120 VAC | - BURNER #1 LIGHT | ||
| BROWN - 120 VAC | - BURNER #2 LIGHT | ||
| ORANGE - TEMPERATURE SENSOR | |||
| ORANGE - TEMPERATURE SENSOR | |||
| PURPLE - CONTROL POT P2 | |||
| RED | - 12 VDC | - FAN #1 VAPOR HIGH LIMIT | |
| RED | - 12 VDC | - FAN #2 VAPOR HIGH LIMIT | |
| RED | - 12 VDC | - FAN #1 HOUSING HIGH LIMIT | |
| RED | - 12 VDC | - FAN #2 HOUSING HIGH LIMIT | |
| RED | - 12 VDC | - FAN #1 FLAME DETECTION | |
| RED | - 12 VDC | - FAN #2 FLAME DETECTION | |
| RED | - 12 VDC | - FAN #1 PLENUM HIGHT LIMIT | |
| RED | - 12 VDC | - FAN #2 PLENUM HIGHT LIMIT | |
| BLUE | - 12 VDC | - FAN #1 AIR SWITCH | |
| BLUE | - 12 VDC | - FAN #2 AIR SWITCH | |
| RED | - 12 VDC | - LOWER FIXED GRAIN LIMIT | |
| RED | - 12 VDC | - USER SUPPLIED SAFETY | |
| RED | - 12 VDC | - MOTOR OVERLOADS | |
| RED | - 12 VDC | - LOWER ADJUSTABLE GRAIN HIGH LIMIT | |
| YELLOW - 12 VDC |
| - OUT OF GRAIN SENSOR | |
| RED | - 12 VDC | - REAR DISCHARGE SWITCH | |
| RED | - 12 VDC | - 12 VOLT SUPPLY | |
| RED | - 12 VDC | - 12 VOLT SUPPLY | |
| WHITE - 12 VDC NEG - 12 VOLT SUPPLY NEGATIVE | |||
| PURPLE | |||
| PURPLE | |||
| PURPLE - CONTROL POT P1 | |||
| PURPLE - CONTROL POT P3 | |||
| BLACK - 120 VAC |
| - MAXON POWER | |
| WHITE - AC NEUTRAL - BURNER #1 NEUTRAL | |||
| WHITE - AC NEUTRAL - BURNER #2 NEUTRAL | |||
| WHITE - AC NEUTRAL - MAXON NEUTRAL | |||
| YELLOW - 120 VAC | - LOAD POWER | ||
| ORANGE - 120 VAC | - UNLOAD POWER | ||
| ORANGE - 120 VAC | - SCR POWER | ||
| WHITE - AC NEUTRAL - FAN #1 NEUTRAL | |||
| WHITE - AC NEUTRAL - FAN #2 NEUTRAL | |||
| WHITE - AC NEUTRAL - UNLOAD NEUTRAL | |||
| WHITE - AC NEUTRAL - LOAD NEUTRAL | |||
| WHITE - AC NEUTRAL - SCR NEUTRAL | |||
| BLACK - 120 VAC |
| - BURNER #1 POWER | |
| BLUE | - 120 VAC | - FAN #1 POWER | |
| BLACK - 120 VAC |
| - BURNER #2 POWER | |
| BLUE | - 120 VAC | - FAN #2 POWER |
EMERGENCY COOLING JUMPERS INSTALL
I/O BOARD JUMPERS INSTALL
45 - D01-0531 ENTRELEC TERMINALS
2 -
1 -
19