54
6 | 5 | 4 |
|
|
MOISTURE
CONTROL
THERMOSTAT
USING OHM METER BEGIN CHECKING THE SENSORS FOLLOWING FIG. 1
IF OHMS DOES NOT = 3.4 K
CHECK LOWER AND UPPER TERMINAL STRIP (ON SINGLE MODULES CHECK S1 & S2) (ON DOUBLE OR TRIPLE MODULES
CHECK
Test Procedure
Wiring Reference
1 | 2 | 3 | 7 | 8 | 9 |
S1 | S2 |
|
|
|
|
IF MEASUREMENTS DO NOT = 3.4 K
CHECK CONNECTIONS IN WHITE
JUNCTION BOX ON FAR LEFT AND
RIGHT SIDES FACING THE FAN END.
FIG.1 | IF NONE OF THE MEASUREMENTS = 3.4 K, |
THEN CHECK EACH INDIVIDUAL SENSOR. | |
3.4 ON 20K |
|
SCALE AT |
|
70 DEGREES
for E.M.C.S. Dryers
Portable Dryer Troubleshooting