Heat & Glo LifeStyle XLR-N-AU, XLR-PB-AU Top Vent Horizontal Termination Venting with 1 elbow

Models: XLR-N-AU XLR-PB-AU

1 70
Download 70 pages 40.41 Kb
Page 25
Image 25

WARNING

Fire Risk. Explosion Risk.

Do NOT pack insulation or other combustibles between ceiling firestops.

ALWAYS maintain specified clearances around venting and firestop systems.

Install wall shield and ceiling firestops as specified.

Failure to keep insulation or other material away from vent pipe may cause fire.

Top Vent - Horizontal Termination

Venting with 1 elbow

V Minimum

H1 Maximum

90 Elbow

1-1/2 ft. (457 mm)

 

 

1 ft. (305 mm)

3 ft. (914 mm)

 

 

1-1/2 ft. (457 mm)

3-1/2 ft. (1067 mm)

 

 

2 ft. (610 mm)

5 ft. (1.52 m)

 

 

2.5 ft. (762 mm)

6 ft. (1.85 m)

 

 

3 ft. (914 mm)

7 ft. (2.13 m)

 

 

3.5 ft. (1066 mm)

10 ft. (3.05 m)

 

 

4 ft. (1.2 m)

15 ft. (4.6 m)

 

 

H Max. = 15 ft. (4.6 m)

V + H Max. = 40 ft. (12.2 m)

Note: Use SLP Series components only.

H1

V1

Figure 7.3

Heat & Glo • XLR-N-AU, XLR-PB-AU2198-906 Rev. M • 5/12

25

Page 25
Image 25
Heat & Glo LifeStyle XLR-N-AU, XLR-PB-AU manual Top Vent Horizontal Termination Venting with 1 elbow, Minimum Maximum