B. Mantel and Wall Projections

WARNING! Risk of Fire! Comply with all minimum clear- ances to combustibles as specified. Framing closer than the minimums listed must be constructed entirely of noncom- bustible materials (i.e., steel studs, concrete board, etc.) Failure to comply could cause fire.

Note: For non-combustible fireplace finish material (marble, stone, etc) specifications refer to Section 13.C.

Mantels (Combustible/Non-Combustible)

3/8 in. (10 mm)

 

Thick Wall

 

Sheathing

11-3/4 in. (300 mm)

 

MAX.

MEASUREMENT

14 in. FROM TOP OF

(360 mm) FIREPLACE MIN. OPENING

Figure 13.7 Clearances To Combustible Mantels Or Other

Combustibles Above Appliance

Note: For non-combustible fireplace finish material (marble, stone, etc) specifications refer to Section 13.C.

Mantel Leg (Combustible/Non-Combustible)

TOP VIEW

 

3 in.

UNLIMITED

(80 mm)

MIN.

 

7 in.

 

(180 mm)

 

Figure 13.8 Non-Combustible Mantel Leg or Wall

Projections

 

(Acceptable on both sides of opening)

Front Side Finishing Detail

 

1-1/4 in. (30 mm)

 

FRAMING

 

1-1/2 in. (37 mm)

 

3/8 in. (10 mm) BUILDING MATERIAL

Figure 13.9

Front Side Finishing Detail

Heat & Glo • XLR-N-AU, XLR-PB-AU2198-906 Rev. M • 5/12

49

Page 49
Image 49
Heat & Glo LifeStyle XLR-N-AU, XLR-PB-AU manual TOP View Unlimited