Heat & Glo LifeStyle XLR-PB-AU, XLR-N-AU manual SLP-HRC-SS SLP-HRC-ZC-SS Horizontal Termination CAP

Models: XLR-N-AU XLR-PB-AU

1 70
Download 70 pages 40.41 Kb
Page 66
Image 66

C. Vent Components Diagrams (continued)

Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be used on a wall 4 in. (102 mm) to 7-1/4 in. (184 mm) thick. If wall thickness is less than 4 in. (102 mm) the existing heat shields must be field trimmed. If wall thickness is greater than 7-1/4 (184 mm) a DVP- HSM-B will be required.

8 in.

(203 mm)

Heat

Shield

15 in.

(384 mm)

 

Max

12 in.

Effective

(305 mm)

Length

SLP-TRAP

Horizontal Termination Cap

Term Cap

Minimum

Maximum

Effective Length

Effective Length

 

Trap

5-1/4 in.

9-1/4 in.

 

(133 mm)

(235 mm)

8 in.

(206 mm)

15in.

(381 mm)

13in.

(330 mm)

Effective Length

5-3/4 in. to 8-3/8 in.

(146 mm to 213 mm)

5-1/2 in.

8-3/8 in.

(140 mm)

(213 mm)

87°

10-1/2 in.

(267 mm) 11 in. (276 mm)

SLP-HRC-SS

SLP-HRC-ZC-SS

HORIZONTAL TERMINATION CAP

Figure 17.7 SLP Series Vent Components

66

Heat & Glo • XLR-N-AU, XLR-PB-AU2198-906 Rev. M • 5/12