1. Top Vent - Horizontal Termination - (continued)

 

 

Top Vent - Horizontal Termination

 

 

Venting with 2 elbows

 

 

 

 

 

V Minimum

 

H1 + H2 Maximum

 

Note: Use SLP Series

90 Elbow

 

1-1/2 ft. (457 mm)

 

components only.

1 ft. (305 mm)

 

3 ft. (914 mm)

 

 

 

 

 

 

 

1-1/2 ft. (457 mm)

 

3-1/2 ft. (1067 mm)

 

 

2 ft. (610 mm)

 

5 ft. (1.52 m)

 

 

 

 

 

 

 

2.5 ft. (762 mm)

 

6 ft. (1.85 m)

 

 

 

 

 

 

 

3 ft. (914 mm)

 

7 ft. (2.13 m)

 

 

 

 

 

 

 

3.5 ft. (1066 mm)

 

10 ft. (3.05 m)

 

 

 

 

 

 

 

4 ft. (1.2 m)

 

15 ft. (4.6 m)

 

 

 

 

 

 

 

H + H1

Max. = 15 ft. (4.6 m)

 

 

V + H + H1 Max. = 40 ft. (12.2 m)

 

 

H2

H1

 

INSTALLED

HORIZONTALLY

V1

Figure 7.4

26

Heat & Glo • XLR-N-AU, XLR-PB-AU2198-906 Rev. M • 5/12

Page 26
Image 26