C. Facing Material
•Facing and/or finishing materials must not interfere with air flow through louvers, operation of louvers or doors, or access for service.
•Facing and/or finishing materials must never overhang into the glass opening.
•Observe all clearances when applying combustible materials.
WARNING! Risk of Fire! DO NOT apply combustible materials beyond the minimum clearances. Comply with all minimum clearances to combustibles as specified in this manual. Overlapping materials could ignite and will interfere with proper operation of doors and louvers.
WARNING! Risk of Fire! DO NOT install drywall or other combustible materials over the
Decorative facing material thickness is measured from the face of the
0 - 1 in. (0 - 25) mm THICK
TONIC DECORATIVE
FRONT SHOWN
0 - 1 in. (0 - 25 mm) THICK
\\\
DRYWALL OR
EQUIVALENT 3/8 in. (10 mm)
Figure 13.11 Overlap Fit Method (Tonic or Martini Decorative Front)
Both the Tonic and Martini decorative fronts can be in- stalled with an “Overlap” or “Inside Fit” method:
Overlap Requirement: See Figure 13.11 and Figure 13.12.
Inside Fit requirement: See Figure 13.13, 13.14, 13.15.
0 - 1 in. (0 - 25 mm)
Both the Tonic and Martini decorative fronts are designed to overlap finish materials 0 in. to 1 in. (0 mm to 25 mm) thick. See Figure 13.11 and Figure 13.12.
NOTICE: This 1 in. (25 mm) maximum not only includes the decorative finish materials (marble, tile, slate, etc) but also the mortar or adhesive used to attach the decorative finish material.
The
0 mm |
0 mm |
0 mm |
0 mm |
Figure 13.12 Non-Combustible Finish Material Diagram for 0 - 1 in. (0 - 25 mm) Thick Overlap Fit Method (Tonic or Martini Decorative Front)
50 | Heat & Glo • |