Top Vent - Vertical Termination

Venting with 2 elbows

V1 Minimum

H Maximum

 

V2

V1 + V2 Minimum

90° Elbow

2 ft. (610 mm)

 

*

*

 

 

 

 

 

6 in. (152 mm)

3 ft. (914 mm)

 

*

*

1-1/2 ft. (457 mm)

5 ft. (1.5 m)

 

*

*

3 ft. (914 mm)

7 ft. (2.1 m)

 

*

*

3-1/2 ft. (1.1 m)

15 ft. (4.6 m)

 

*

*

 

H Max. = 15 ft. (4.6 m)

 

 

 

V1 + V2 + H Max. = 40 ft. (12.2 m)

 

 

* No specific restrictions on this value EXCEPT V1 + V2 + H cannot exceed 40 ft. (12.2 m)

Note: Use SLP Series components only.

V2