12 Electrical Information

A. Wiring Requirements

NOTICE: This appliance must be installed by a qualified electrician in accordance with the relevant national and local regulations.

Wire the appliance junction cord to 220-240 VAC. This is required for proper operation of the appliance.

WARNING! Risk of Shock or Explosion! DO NOT wire 220/240 VAC to the valve or to the appliance wall switch. Incorrect wiring will damage controls.

NOTICE: The mains supply to the appliance must have isolation of a minimum 3 mm contact separation in both poles.

WARNING! Risk of Injury! The gas supply shall be shut off prior to disconnecting the electrical power and remov- ing batteries (if installed) before proceeding with any maintenance to the appliance.

B. IntelliFire Plus™ Ignition System Wiring

Wire the appliance junction cord to 220-240 VAC for proper operation of the appliance.

WARNING! Risk of Shock or Explosion! DO NOT wire IPI controlled appliance junction cord to a switched cir- cuit. Incorrect wiring will override IPI safety lockout.

Refer to Figure 12.1, IntelliFire Plus™ Pilot Ignition (IPI) Wiring Diagram.

This appliance is equipped with an IntelliFire Plus™ control valve which operates on a 6 volt system.

For units installed in Australia, the residence’s 220/240 wall outlet to which this appliance’s power cord is con- nected, must be wired to an in-line on/off switch. This is required for servicing and/or resetting the control module in the event of a control module LOCK-OUT.

Plug the 6-volt AC power supply into the appliance junction cord to supply power to the unit.

C. Optional Accessories Requirements

This appliance may be used with a wall switch, wall mounted thermostat and/or a remote control.

Wiring for optional Hearth & Home Technologies approved accessories should be done now to avoid reconstruction. Follow instructions that come with those accessories.

Optional Remote Control Receiver Location

The control module and remote control receiver can be accessed through the air space between the firebox front and the lower-front finishing cover panel. The decora- tive front and glass assembly must be removed to access these components.

The IPI control module and the remote control receiver are placed on the firebox bottom.

TO JUNCTION CORD

JUNCTION CORD

FLAME

SENSE

GRAY MODULE

NOTE: 1. Ignition module, valve, pilot, and wall switch operate on 6 volts. 220/240 VAC is required at junction cord.

IGNITER

RC300 4.5V DC (AA X 3)

RC100

(OPTIONAL REMOTE CONTROL)

ORANGE (PILOT)

GREEN

 

(MAIN)

BLACK

RED

THERMOSTAT WIRE

 

BROWN

ASSEMBLY / WALL

SWITCH WIRE

 

GROUND

Figure 12.1 IntelliFire Plus™ Pilot Ignition (IPI) Wiring Diagram with Wall Switch or Thermostat

44

Heat & Glo • XLR-N-AU, XLR-PB-AU2198-906 Rev. M • 5/12

Page 44
Image 44
Heat & Glo LifeStyle XLR-PB-AU manual Electrical Information, Wiring Requirements, IntelliFire Plus Ignition System Wiring