FIREPLACE OPENING

15-3/4 in. TO 16 in.

(400 mm TO 410 mm)

Figure 13.4 Required Fireplace Opening Height

Note: The lower cover panel must be pushed all the way down. The outer finishing flanges should line up. The fireplace opening must be between 15-3/4 in. and 16 in. (400 mm and 410 mm) for the decorative fronts to fit correctly. See Figure 13.4, Figure 13.5 and Figure 13.6.

Sealing Joints

All joints between the factory-installed non-combustible board and 3/8 in. (10 mm) building material (dry wall, plywood, wood composites, etc.) can be taped and sealed with combustible drywall tape.

RIGHT SIDE

FINISH

FLANGE

LOWER FINISH FLANGE

BOTTOM COVER PANEL

Figure 13.5 Lower Cover Panel Positioned Incorrectly.

RIGHT SIDE

FINISH

FLANGE

LOWER FINISH FLANGE

BOTTOM COVER PANEL

Figure 13.6 Lower Cover Panel Positioned Correctly

48

Heat & Glo • XLR-N-AU, XLR-PB-AU2198-906 Rev. M • 5/12

Page 48
Image 48
Heat & Glo LifeStyle XLR-PB-AU, XLR-N-AU manual Sealing Joints, Required Fireplace Opening Height