G. Air Shutter Setting

Air shutter settings may be adjusted by a qualified install- er at the time of installation. The air shutter is set at the factory for minimum vertical vent run. Adjust air shutter for longer vertical runs. See Figure 14.2.

Loosen the 1/4 in. (6 mm) screw.

Twist shutter to adjust

Shutter may be open for longer horizontal vent runs.

Do not close the air shutter more than 5/8 in. (16 mm) for NG or 3-1/8 in. (80 mm) for LP. Note: the air shutter should be fully open when using butane.

Tighten the screw.

NOTICE: If the flames appear to be orange, open the air shutter to prevent residue buildup on the glass.

Figure 14.2 Air Shutter

Shutter Settings - Glass Media and Media-Stones-2

 

USA/Canada

Europe

AU

NZ

NG

1/16 in.

.2 cm

2 mm

2 mm

LP (Propane)

5/16 in.

.8 cm

8 mm

8 mm

 

 

 

 

 

Butane*

N/A

Full Open

Full Open

Full Open

 

 

 

 

 

*Butane gas is only approved for use in Europe, Australia, and New Zealand

Shutter Settings - XLR Logs

 

USA/Canada

Europe

AU

NZ

 

 

 

 

 

NG

3/16 in.

.5 cm

5 mm

7 mm

 

 

 

 

 

LP (Propane)

7/16 in.

1.1 cm

11 mm

11 mm

Butane*

N/A

Full Open

Full Open

Full Open

*Butane gas is only approved for use in Europe, Australia, and New Zealand

H. Media Options

Unit ships without a media option. Available approved media options are:

MEDIA-AMBER

MEDIA-BLACK

MEDIA-CLEAR

MEDIA-COBALT

MEDIA-BK2-GEMS

MEDIA-WH2-GEMS

MEDIA-GEMS

PORC-BASE

XLR-LOGS

MEDIA-STONES-2

I. Verify Performance of Appliance

1.Verify pilot sparks, pilot lights, pilot stops sparking, and the main burner turns “ON” by turning wall control “ON”.

2.Turn fireplace OFF. Verify that the both the pilot and burner turn “OFF”.

3.Repeat Step 1 above.

4.With the burner “ON” remove the green wire connected to the gas valve after the second audible “beep” from the control module is heard. The main burner should shut off. Turn appliance “OFF”.

5.Reattach the green wire to the valve and turn ON the fireplace. The main burner should light after the second audible “beep” from the control module is heard.

6.With the main burner ON, remove the green wire con- nected to the gas valve after the second audible “beep” from the control module is heard. The main burner should shut off.

7.Turn fireplace “OFF” and reattach orange wire to the valve.

54

Heat & Glo • XLR-N-AU, XLR-PB-AU2198-906 Rev. M • 5/12

Page 54
Image 54
Heat & Glo LifeStyle XLR-PB-AU, XLR-N-AU manual Air Shutter Setting, Media Options, Verify Performance of Appliance