2. Product does not operate at all.

LJ

(" Refer to Electronic Control Device drawing and Schematic diagram.)

Turn off Main Power

.Cý_ (After 10 seconds)

Tum on Main Power

Does "beeping" sound is made from the Indoor Unit?

NO

Check the voltage of power(About AC 208V/AC230V, 60HZ)

YES

Primarily, the operating condition of Micom is OK.

Main power's voltage

Voltage applied to the unit

Connecting method of Indoor/Outdoor connecting cable

Check PWB Ass'y(Outdoor unit)

-Fuse

-Pattern damage

-Varistor(ZNRI)

Check the connection housing for contacting

"Connector related to CN-POWER

"Connector related to CN-FAN

"Connector contacting of Outdoor Fan/Compressor

"Display PWB Ass'y Check

"Connector related to CN-DC/DC

Check each load(Indoor/Outdoor Fan Motor,

Compressor, Stepping Motor) and contacting condition of related connector(including connecting cable of Indoor/Outdoor Unit)

 

PCB Board Operation Check

 

Items

Content

Remedy

" Power Transformer

 

 

(Outdoor unit)

 

 

Input Voltage

-About AC208V/230V&10% -Check the power voltage

" Replace Trans

Output Voltage

About AC17t3V

 

I&

 

 

" IC2(7812) Output

" DC +12V

" Replace IC2

(Indoor/Outdoor unit)

 

 

4

 

" Replace IC3

" IC3(7805) Output

" DC +5V

(Indoor/Outdoor unit)

 

 

I&

 

 

" IC4(KIA7036, Reset IC)

" Voltage of Outdoor unit Micom No. 8,

" Replace faulty parts

X01(4MHz)

Voltage of Indoor unit Micom No. 43 and soldering

 

(Indoor/Outdoor unit)

condition

 

 