Heat Controller MSH-01 2B/A Modeo, MODE1rStart, MODE2 MODE3 MODE4 Modes, End, MODE6 MODE9 Closed

Models: MSH-01 2B/A MSH-024B/A MSS-024B/A MSH-0186/A MSS-018B/A MSS-009B/A MSS-012B/A

1 86
Download 86 pages 29.35 Kb
Page 16
Image 16

Auto Operation for Soft Dry(only Heating Model)

"The Setting temperature will be same that of the auto operation for cooling.

-Compressor ON temperature; Setting temperature +2°F

-Compressor OFF temperature; Setting temperture -1 °F

Intake-air temp.

below WF

Over 68°F-below 70°F

over 86°F

Setting terrp.

68°F

Intake air temperature +1°F

86°F

Auto Operation for Heating(only Heating Model)

-Compressor ON temperature; Setting temperature

-Compressor OFF temperature; Setting temperature +6°F

Vertical louver auto operation : In Auto operation mode, when pressing the vertical airflow direction control button, vertical louver moves as shown below.

MODEO

MODE1rStart

MODE2

MODE3

MODE4

MODES

/End

MODE6

MODE9

(CLOSED)