OUTDOOR UNIT

Connector Type

CN-POWER

RY-COMP

terminal

CN-TRANS

CN-FAN

The connecting

wire of CN- DC1DC, and

Indoor and

Outdoor Unit

O ®(ýO

"

0 Blue

® Black

® Brown

® Red

Condition

OPEN

Connecting reversely

OPEN

Connecting reversely

OPEN

OPEN

OPEN

Connecting error

l +0 , ý)

Connecting error

(G) `" ©)

Connecting error

(©ý ®)

Connecting error

Connecting error

(®ý ©)

Connecting error

Phenomena

"All functions stop.

"The operation with the remote controller, forced and test one do not operate.

"PWB pattern is damaged when applying the power.

"An functions stop orthe compressor does not operate.

"The operation with the remote controller, forced and test one do not operate.

"All functions stop.

"The operation with the remote controller, forced and test one do not operate.

"All functions stop.

"The operation with the remote controller, forced and test one do not operate.

"The Indoor Fan does riot operate.

"Ad functions stop.

"The operation with the remote controller, forced and test one do not operate.

"The only signal of remote controller operation/stop is inputted, but the product does not operate.

"The RED kxticator of outdoor unit blinks 5 times after 2 minutes with applying the power.

"The beep sound, such as "beep, beep, beep, beep,

beep", oocurs periodically in Indoor unit.

.The signal input of a remote oontroller and operation of product

. The D Indicator blinks 5 times after 2 nvnutes with applying the power.

"The signal of remote controller is Inputted, but the product does rat operate.

"The RED indicator of outdoor unit and the operation indicator of indoor one blinks 5 times after 2 minutes with applying the power.

"No power for Indoor unit.

"The signal input of the remote controller and opera- tion of product is impossible.

"The thermal protector of the Power Trans operates when let it alone for long time.

"The signal of the remote controller is inputted.

"The fuse and 061 in the Outdoor unit are damaged when the indoor fan is operated.

"No power for Indoor unit.

"The signal input of the remote controller and opera- tion of product is impossible.

"The RED indicator of the Outdoor writ blinks 5 times after 2 minutes with applying the power.