Functions

I Indoor Unit

Operation OWOFF by Remote controller

Sensing the Room Temperature

"Room temperature sensor (THERMISTOR) Room temperature control

"Maintains the room temperature In accordance with the Setting Temp.

Starting Current Control I

"indoor fan is delayed for 5 seconds at the starting. Time Delay Safety Control

"Restarting is inhibited for approx. 3 minutes.

Indoor Fan Speed Control

" High, Med, Low and Auto

Operation Indication Lamps (LED)

ýi --- Lights up in operation

---Lights up in Sleep Mode

---Lights up in Timer Mode

---Lights up in Defrost Mode or Hot Start Mode (only Heating Model)

OUT -- Lights up during compressor running (only Cooling Model)

DOOR

Soft Dry Operation Mode

"Intemrittent operation of fan at low speed

Sleep Mode Auto Control

"The fan is switched to low(Cooling), med(Heating) speed.

"The trait will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.

Auto Air Control by the unit electronic controlI

"The fan is swilched to intermittent or irregular operation.

" The fan speed is automatically switched from high to low speed.

Airflow Direction Control I

The louver can be set at the desired position or swing up

and down automatically.

AUTO Wind

" The fan speed is automatically switched from high to low speed.

Defrost control(Heating)

"Both the indoor and outdoor fan stops during defrosting.

*Hot start will be operated after defrosting ends.

Hot-start Control (Heating)

"The indoor fan stops until the indoor pipe temperature will be reached at 28°C(82"F).

-3-