Heat Controller MSS-012B/A, MSH-0186/A, MSS-018B/A, MSH-01 2B/A When Indoor Fan does not operate

Models: MSH-01 2B/A MSH-024B/A MSS-024B/A MSH-0186/A MSS-018B/A MSS-009B/A MSS-012B/A

1 86
Download 86 pages 29.35 Kb
Page 53
Image 53

U

5. When Indoor Fan does not operate.

Does the voltage of each terminals of CN-MOTOR CONNECTOR in

Indoor unit corresponds to values In the Table of page 517

_C3-

ltage oof!terminal CN-DC/DC CONNECTOR in Indcor unft corresponds to the values in the table of page 51?

Check connecting condition of the CN-MOTOR CONNECTOR

\/

Do the vonage ofterminal of CN-

Check the pattern and the

DCM CONNECTOR in

condition of indoor unit PWB

Outdoor unit corresponds to the

Assy

values in the table of page 51?

 

\/

Check the interference of Indoor Fan.

NOyF.S

Check the patterns and the

Check the connecting cons l-

Check the motor of Indoor Fan

ton and disconnection of

 

cond'nions of outdoor unit

 

connecting wires between

 

PWB ions o

 

AssYs.

Indoor and Outdoor unit.

 

 

 

"

"

"

Indoor Fan may be stopped in the Soft Dry Mode(change to the Cooling Operation Mode). Indoor Fan is to be stopped when Indoor pipe(ooil) termperature is lower than 79°F.

(At that tunes, Defrost indicator is turned on)

-53-

"