Heat Controller MSH-0186/A Phenomena in case of connecting error, Indoor Unit, Cn-Up/Down, Cn-Th

Models: MSH-01 2B/A MSH-024B/A MSS-024B/A MSH-0186/A MSS-018B/A MSS-009B/A MSS-012B/A

1 86
Download 86 pages 29.35 Kb
Page 56
Image 56

8.The phenomena in case of connecting error

INDOOR UNIT

0

Connector Type

Condition

CN-DC/DC

Open and connecting error

pBlue

Q Black

(D Brown © Red

CN-MOTOROpen

Open

CN-UP/DOWN

Short between terminals

CN-DISPOpen

Open

Phenomena

" The same as the phenomenon of Outdoor Unit.

-The indoor fan does not operate.

"The operation indicator of Indoor unit blinks 8 times.

"The up/down vane does not operate.

"The up/down vane does not smoothly operate.

"It does not operate with a remote controller.

"The operation indicator blinks once.

On for 0.5 second

Ott ior 3 seconds

" The compressor and the outdoor fan stop. " The indoor fan speed is low.

CN-TH

 

" The operation indicator blinks once

Short between terminals

 

(on for 0.5 second, off for 3 seconds).

 

The compressor operates continuously regardless

((I and ®) of ROOM-TH.

"

of the setting temperature and the variation of room

 

 

 

 

temperature.

Short between terminals

" The operation indicator blinks once

(T and ®) of PIPE-TH.

 

(on for 0.5 second, off for 3 seconds)

 

" Continuous operation

"

-56-

0

Page 56
Image 56
Heat Controller MSH-0186/A, MSS-018B/A, MSH-01 2B/A Phenomena in case of connecting error, Indoor Unit, Cn-Up/Down, Cn-Th