2) Connection of Pipings

1.Remove the indoor tubing with Drain hose from the hole

"Remove tubing hider and pull the tubing out of the chassis.

2.Replace the tubing holder into original position.

"Recommended SPEC. of a additional Drain Hose.

Joint Part

The material of Drain hose

Inner size

Material

 

MAX.

soft PVC

Soft PVC hose

ol(imm(SV)

In9beWM dedwihW koMm MaWA

"Foamed Polyethylene or equivalent Is recommended.

CAUTION: The unit's drain hose and additional drain hose must be sealed up by adhesive or tape.

For right rear piping

3.Route the tubing and the drain hose straight backwards.

4.Insert the connecting cable into the indoor unit through the piping hole.

"Do not connect the cable to the indoor unit.

"Make a small loop with the cable for easy connection later.

5.Tape the tubing, drain hose and the connecting cable. Be sure that drain hose locates at the lowest side of the bundle. Locating at the upper side can be a reason that drain water overflows drain pan inside the untL

It the drain hose will run in the room, insulate the

hose with an Insulation material' so that dripping from "sweating"(condensation) will not damage

furniture or floors.

"Foamed polyethylene or equivalent is recommended.

Tubing

 

To remove the holder,

 

press the bottom of

 

chassis near the holder

 

upward and pull the tab

Press

out of its hole.

0

-28-

L_ý

Page 28
Image 28
Heat Controller MSH-0186/A, MSS-018B/A, MSH-01 2B/A, MSS-009B/A, MSS-012B/A manual Connection of Pipings, For right rear piping