Henny Penny 500, 600 warranty Henny Penny Part No. 19921, which complies with

Models: 500 600

1 66
Download 66 pages 6.22 Kb
Page 17
Image 17
(Henny Penny Part No. 19921), which complies with

Model 500/600

2-7. GAS PIPING

(Henny Penny Part No. 19921), which complies with

(Continued)

ANSI standard Z21.41, or CAN 1-6.9. Also adequate

 

means must be provided to limit the movement of the

 

fryer without depending on the connector and quick-

 

disconnect device or its associated piping to limit the

 

fryer movement.

 

3. See the illustration on following page for the proper connec-

 

tions of the flexible gas line and cable restraint.

The cable restraint limits the distance the fryer can be pulled from the wall. For cleaning and servicing the fryer, the cable must be unsnapped from the unit and the flexible gas line disconnected. This will allow better access to all sides of the fryer. The gas line and cable restraint must be reconnected once the cleaning and servicing is complete.

1207

2-7

Page 17
Image 17
Henny Penny 500, 600 warranty Henny Penny Part No. 19921, which complies with