| Model 500/600 | |
ERROR CODES | This section provides error codes and their | |||
|
|
| information in the form of an | |
|
|
| If a problem occurs during the first operation of a | |
|
|
| new fryer, recheck the Installation Section . | |
ERROR CODE TABLE | In the event of a control system failure, the digital | |||
|
|
| display shows an error message coded as follows: | |
|
|
| ||
|
|
| ||
|
|
| An alarm sounds when an error code is displayed, | |
|
|
| and to silence this alarm, press any button. | |
|
|
|
|
|
| DISPLAY | CAUSE | PANEL BOARD CORRECTION |
|
|
|
|
| |
Control board | Turn switch to OFF position, then turn switch back to ON; |
| ||
“CPU TOO | overheating | if display shows |
| |
| HOT” |
| check the louvers on each side of the unit for obstructions; |
|
|
|
| check cooling fan, if present |
|
|
|
|
| |
Shortening | Turn switch to OFF position, then turn switch back to ON; if |
| ||
TOO HOT” | overheating | display shows |
| |
|
|
| probe should be checked |
|
|
|
|
| |
Temperature | Turn switch to OFF position; then turn switch back to ON; if |
| ||
“OIL PROB | probe open | display shows |
| |
| OPEN” |
|
|
|
|
|
|
| |
Temperature | Turn switch to OFF position, then turn switch back to ON; if |
| ||
“OIL PROB | probe shorted | display shows |
| |
| SHRT” |
|
|
|
|
|
|
| |
Highlimit | Reset the high limit by manually pushing up on the reset |
| ||
“HIGH |
| button; if high limit does not reset, high limit must be |
| |
| LMT TRIP” |
| replaced |
|
|
|
|
|
|
1207 |