The gas pressure regulator on the automatic gas valve

Model 500/600

2.8GAS LEAK TEST

Prior to turning the gas supply on, be sure the gas valve knob on the gas control valve is in the OFF position.

After the piping and fittings have been installed, check for gas leaks.A simple checking method is to turn on the gas and brush all connections with a soap solution. If bubbles occur, it indicates escaping gas. In this event, the piping connection must be redone.

To avoid fire or explosion, never use a lighted match or open flame to test for gas leaks. Ignited gas could result in severe personal injury and/or property damage.

2-9. GAS PRESSURE

The gas pressure regulator on the automatic gas valve

REGULATOR SETTING

is factory set as follows:

 

 

Natural: 3.5 inches water column (0.87 kPa)

 

 

Propane: 10.0 inches water column (2.49 kPa)

 

 

The gas pressure regulator has been set by Henny Penny and

 

 

is not to be adjusted by the user.

2-10. GAS PILOT & BURNER

Lighting Procedure - Solid State Ignition

LIGHTINGAND

1.

The frypot should be cleaned per the instructions in Section 3.

SHUTDOWN

2.

The frypot must be filled to the proper level with shortening.

PROCEDURE

 

 

Refer to Filling orAdding Shortening Section.

 

3.

Turn main power switch to OFF position.

 

4.

Turn the gas valve knob counterclockwise to the OFF position.

 

 

(OFF pointed down)

 

5.

Wait a sufficient length of time (at least 5 minutes) to allow any gas

 

 

which may have accumulated in the burner compartment to escape

Step 4

6.

Turn the gas valve knob clockwise to the ON position.

 

 

(ON pointed down)