3-2. ERROR CODE TABLE

 

 

 

Model 500/600

3-2. ERROR CODE TABLE

 

 

 

(Continued)

 

 

 

 

 

 

 

 

 

DISPLAY

CAUSE

PANEL BOARD CORRECTION

 

 

 

 

 

 

 

“E-15”

Drain switch

Close drain, using the drain valve handle; if display still

 

 

“DRAN IS

failure

shows “E-15”, have the drain microswitch checked

 

 

OPEN”

 

 

 

 

 

 

 

 

 

“E-20C”

Ignition module(s)

Turn switch to OFF, then back to COOK to try the ignition

 

 

(SSI gas fryers

failure

process again, and if “E-20C” persists, have ignition modules

 

 

only)

 

checked

 

 

 

 

 

 

 

“E-20D”

No ignition

Turn switch to OFF, then back to COOK to try the ignition

 

 

(SSI gas fryers

 

process again, and if “E-20D” persists, have gas valve and gas

 

 

only)

 

flow checked

 

 

 

 

 

 

 

“E-41”

Programming

Turn switch to OFF, then back to COOK; if display shows any

 

 

“E-46”

failure

of the error codes, try to reinitialize the control (Section 2-3);

 

 

 

 

if error code persists, have the control board replaced

 

 

 

 

 

 

 

“E-70A”

Missing or broken

Have jumper wire between pins 1 and 2 checked

 

 

 

wire in pins 1 and

 

 

 

 

2 of P11 connector,

 

 

 

 

or faulty connector

 

 

 

 

Faulty I/O board

Have I/O board checked and replaced, if necessary

 

 

 

 

 

 

 

“TEMP TOO”

Possible water

Make sure oil is in frypot and at the proper level

 

 

LOW FOR

in frypot

 

 

 

PRESSURE”

 

 

 

 

 

 

 

 