Control constants

 

 

 

 

 

Default

 

Code

Function name

Monitored data or setting

 

 

 

 

Note

 

 

 

_FF

 

_FEF

_FUF

 

 

 

00 (disabling auto-tuning), 01 (auto-tuning without rotation), 02 (auto-tuning

 

 

 

 

 

H001

Auto-tuning Setting

 

00

 

 

with rotation)

 

 

 

 

 

 

 

 

 

 

H002

Motor data selection, 1st motor

00 (Hitachi standard data), 01 (auto-tuned data),

 

00

 

 

02 (auto-tuned data [with online auto-tuning function])

 

 

 

 

 

 

 

 

 

 

H202

Motor data selection, 2nd motor

00 (Hitachi standard data), 01 (auto-tuned data),

 

00

 

 

02 (auto-tuned data [with online auto-tuning function])

 

 

 

 

 

 

 

 

 

 

H003

Motor capacity, 1st motor

0.20 to 75.00 (kW)

 

Factory setting

 

H203

Motor capacity, 2nd motor

0.20 to 75.00 (kW)

 

Factory setting

 

H004

Motor poles setting, 1st motor

2, 4, 6, 8, 10 (poles)

 

4

 

 

H204

Motor poles setting, 2nd motor

2, 4, 6, 8, 10 (poles)

 

4

 

 

H005

Motor speed constant, 1st motor

0.001 to 9.999, 10.00 to 80.00 (10.000 to 80.000)

 

1.590

 

 

H205

Motor speed constant, 2nd motor

0.001 to 9.999, 10.00 to 80.00 (10.000 to 80.000)

 

1.590

 

 

H006

Motor stabilization constant, 1st

0. to 255.

 

100.

 

 

motor

 

 

 

 

 

 

 

 

 

 

H206

Motor stabilization constant, 2nd

0. to 255.

 

100.

 

 

motor

 

 

 

 

 

 

 

 

 

 

H306

Motor stabilization constant, 3rd

0. to 255.

 

100.

 

 

motor

 

 

 

 

 

 

 

 

 

 

H020

Motor constant R1, 1st motor

0.001 to 9.999, 10.00 to 65.53 ()

Depending on motor capacity

 

H220

Motor constant R1, 2nd motor

0.001 to 9.999, 10.00 to 65.53 ()

Depending on motor capacity

 

H221

Motor constant R2, 1st motor

0.001 to 9.999, 10.00 to 65.53 ()

Depending on motor capacity

 

H221

Motor constant R2, 2nd motor

0.001 to 9.999, 10.00 to 65.53 ()

Depending on motor capacity

 

H222

Motor constant L, 1st motor

0.01 to 99.99, 100.0 to 655.3 (mH)

Depending on motor capacity

 

H222

Motor constant L, 2nd motor

0.01 to 99.99, 100.0 to 655.3 (mH)

Depending on motor capacity

 

H223

Motor constant Io

0.01 to 99.99, 100.0 to 655.3 (A)

Depending on motor capacity

 

H223

Motor constant Io, 2nd motor

0.01 to 99.99, 100.0 to 655.3 (A)

Depending on motor capacity

 

H224

Motor constant J

0.001 to 9.999, 10.00 to 99.99, 100.0 to 999.9, 1000. to 9999.

Depending on motor capacity

 

H224

Motor constant J, 2nd motor

0.001 to 9.999, 10.00 to 99.99, 100.0 to 999.9, 1000. to 9999.

Depending on motor capacity

 

H030

Auto constant R1, 1st motor

0.001 to 9.999, 10.00 to 65.53 ()

Depending on motor capacity

 

H230

Auto constant R1, 2nd motor

0.001 to 9.999, 10.00 to 65.53 ()

Depending on motor capacity

 

H231

Auto constant R2, 1st motor

0.001 to 9.999, 10.00 to 65.53 ()

Depending on motor capacity

 

H231

Auto constant R2, 2nd motor

0.001 to 9.999, 10.00 to 65.53 ()

Depending on motor capacity

 

H232

Auto constant L, 1st motor

0.01 to 99.99, 100.0 to 655.3 (mH)

Depending on motor capacity

 

H232

Auto constant L, 2nd motor

0.01 to 99.99, 100.0 to 655.3 (mH)

Depending on motor capacity

 

H233

Auto constant Io, 1st motor

0.01 to 99.99, 100.0 to 655.3 (A)

Depending on motor capacity

 

H233

Auto constant Io, 2nd motor

0.01 to 99.99, 100.0 to 655.3 (A)

Depending on motor capacity

 

H234

Auto constant J, 1st motor

0.001 to 9.999, 10.00 to 99.99, 100.0 to 999.9, 1000. to 9999.

Depending on motor capacity

 

H234

Auto constant J, 2nd motor

0.001 to 9.999, 10.00 to 99.99, 100.0 to 999.9, 1000. to 9999.

Depending on motor capacity

 