Code

 

b034

 

 

b035

Others

b036

b037

 

b038

 

b039

 

b040

limitation

b041

b042

Torque

b043

 

 

b044

 

b045

 

b046

power

b050

b051

momentaryatoperation failure

b052

 

 

b053

Non-stop

b054

b056

 

b055

 

b060

 

b061

 

b062

 

b063

comparator

b064

b065

 

Window

b066

b067

 

 

b068

 

b070

 

b071

 

b072

 

 

 

 

 

Default

 

 

Function name

Monitored data or setting

 

 

 

Note

 

 

_FF

_FEF

_FUF

 

 

 

 

 

 

 

Run/power-on warning time

0. to 9999. (0 to 99990), 1000 to 6553 (10000 to 655300) (hr)

 

0.

 

 

Rotational direction restriction

00 (enabling both forward and reverse rotations), 01 (enabling only

 

00

 

 

forward rotation), 02 (enabling only reverse rotation)

 

 

 

 

 

 

 

 

Reduced voltage start selection

0 (minimum reduced voltage start time) to 255 (maximum reduced voltage

 

6

 

 

start time)

 

 

 

 

 

 

 

 

Function code display restriction

00 (full display), 01 (function-specific display), 02 (user setting), 03 (data

 

04

 

 

comparison display), 04 (basic display)

 

 

 

 

 

 

 

 

Initial-screen selection

00 (screen displayed when the STR key was pressed last), 01 (d001), 02

 

01

 

 

(d002), 03 (d003), 04 (d007), 05 (F001)

 

 

 

 

 

 

 

 

Automatic user-parameter

00 (disabling), 01 (enabling)

 

00

 

 

setting function enable

 

 

 

 

 

 

 

 

Torque limit selection

00 (quadrant-specific setting), 01 (switching by terminal), 02 (analog

 

00

 

 

input), 03 (option 1), 04 (option 2)

 

 

 

 

 

 

 

 

Torque limit (1) (forward-driving

0. to 200. (%), no (disabling torque limitation)

 

150.

 

 

in 4-quadrant mode)

 

 

 

 

 

 

 

 

Torque limit (2)

 

 

 

 

 

(reverse-regenerating in

0. to 200. (%), no (disabling torque limitation)

 

150.

 

 

4-quadrant mode)

 

 

 

 

 

Torque limit (3) (reverse-driving

0. to 200. (%), no (disabling torque limitation)

 

150.

 

 

in 4-quadrant mode)

 

 

 

 

 

 

 

 

Torque limit (4)

 

 

 

 

 

(forward-regenerating in

0. to 200. (%), no (disabling torque limitation)

 

150.

 

 

4-quadrant mode)

 

 

 

 

 

Torque limit LADSTOP enable

00 (disabling), 01 (enabling)

 

00

 

 

Reverse Run protection enable

00 (disabling), 01 (enabling)

 

00

 

 

Controller deceleration and stop

00 (disabling), 01 (nonstop deceleration to stop), 02 (DC voltage constant

 

00

 

 

on power loss

control, with resume), 03 ( without resume)

 

 

 

 

 

 

 

DC bus voltage trigger level

0.0 to 999.9, 1000. (V)

 

220/440

 

 

during power loss

 

 

 

 

 

 

 

 

Over-voltage threshold during

0.0 to 999.9, 1000. (V)

 

360/720

 

 

power loss

 

 

 

 

 

 

 

 

Deceleration time setting during

0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)

 

1.00

 

 

power loss

 

 

 

 

 

 

 

 

Initial output frequency decrease

0.00 to 10.00 (Hz)

 

0.00

 

 

during power loss

 

 

 

 

 

 

 

 

Proportional gain setting for

0.00 to 2.55

 

0.20

 

 

nonstop operation at power loss

 

 

 

 

 

 

 

 

Integral time setting for nonstop

0.000 to 9.999 /10.00 to 65.53 (s)

 

0.100

 

 

operation at power loss

 

 

 

 

 

 

 

 

Maximum-limit level of window

0. to 100. (lower limit : b061 + b062 / 2) (%)

 

100

 

 

comparators O

 

 

 

 

 

 

 

 

Minimum-limit level of window

0. to 100. (lower limit : b060 - b062 / 2) (%)

 

0

 

 

comparators O

 

 

 

 

 

 

 

 

Hysteresis width of window

0. to 10. (lower limit : b061 - b062 / 2) (%)

 

0

 

 

comparators O

 

 

 

 

 

 

 

 

Maximum-limit level of window

0. to 100. (lower limit : b064 + b066 / 2) (%)

 

100

 

 

comparators OI

 

 

 

 

 

 

 

 

Minimum-limit level of window

0. to 100. (lower limit : b063 - b066 / 2) (%)

 

0

 

 

comparators OI

 

 

 

 

 

 

 

 

Hysteresis width of window

0. to 10. (lower limit : b063 - b064 / 2) (%)

 

0

 

 

comparators OI

 

 

 

 

 

 

 

 

Maximum-limit level of window

-100. to 100. (lower limit : b067 + b068 / 2) (%)

 

100

 

 

comparators OI

 

 

 

 

 

 

 

 

Minimum-limit level of window

-100. to 100. (lower limit : b066 - b068 / 2) (%)

 

0

 

 

comparators O/OI/O2

 

 

 

 

 

 

 

 

Hysteresis width of window

0. to 10. (lower limit : b066 - b067 / 2) (%)

 

0

 

 

comparators O/OI/O2

 

 

 

 

 

 

 

 

Operation level at O

0. to 100. (%) or "no" (ignore)

 

no

 

 

disconnection

 

 

 

 

 

 

 

 

Operation level at OI

0. to 100. (%) or "no" (ignore)

 

no

 

 

disconnection

 

 

 

 

 

 

 

 

Operation level at O2

-100. to 100. (%) or "no" (ignore)

 

no

 

 

disconnection

 

 

 

 

 

 

 

 

1 - 8

Page 12
Image 12
Hitachi SJ700-2 Series service manual B034