Problem

 

Cause

 

Remedy

 

 

 

 

 

 

 

Many malfunctions

 

Some parameters out of adjustment

 

Load “default settings” with Opus or

 

 

 

 

PC software

 

 

 

 

 

Buttons respond too slowly

 

Set incorrectly to “slow”

 

Can be set to “fast” with Opus or PC

 

 

 

 

software

 

 

 

 

 

Buttons “locked” instead of “active”

 

Set incorrectly

 

Can be set with Opus or PC software

 

 

 

 

 

Hydraulic implement cushioning

 

Turned off

 

Turn on with keyboard

inoperative

 

Electronic pressure sensor defective

 

Replace

 

 

 

 

 

Specified pressure too low

 

Change on electric pressure sensor

 

 

Function switched to rear power lift

 

Set to “Front” with Opus

 

 

 

 

 

Implement cushioning pulsing a lot

 

Specified pressure and hysteresis

 

Change pressure sensor settings

 

 

too low or too high

 

 

 

 

 

Implement weight too low

 

Turning off the implement cushioning

 

 

Hydraulic pressure accumulator

 

Renew pressure accumulator

 

 

defective, no cushioning noticeable

 

 

 

 

 

 

 

 

Position control inoperative

 

Actual value transmitter (angle

 

Renew

 

 

sensor) defective

 

 

 

 

 

Angle sensor adjusted incorrectly

 

Readjust acc. to specifications

 

 

Angle sensor with incorrect range

 

Increase higher value with specified

 

 

setting

 

value potentiometer, decrease lower

 

 

 

 

value

 

 

 

 

 

 