Operating instructions

Maintenance every 125 hours

Check the battery and cable terminals

CAUTION

When working on the electrical equipment, always disconnect the ground lead (1) at the battery.

-Check the battery acid level and inspect the battery for leaks. Observe the information of the battery manufacturer.

-Remove any corrosion on the battery terminals.

-Grease the battery terminals with non-acidic battery grease.

-Check cables and cable ends for secure connection and damage.

-Replace any damaged cables and terminals.

Check the high pressure hoses

-Check the high pressure hoses for cracks, bending and chafing, and for porous surfaces.

Replace damaged high-pressure hoses immediately.

This work may only be carried out by an authorized work- shop.