User Setup (cont'd)

Safe Mode

The Safe Mode may be automatically entered by the program on a communication failure or may be entered manually on command.

To Exit the Safe Mode:

1.Press the ! SAFE MODE ! bar.

2.Select “Yes” to return to the Normal Mode of operation. The keypad resets and normal operation returns as long as the original conditions that caused the entry into Safe Mode do not still exist.

ICON

 

ACTION

NOTES

! SAFE MODE !

1.

Select Safe Mode and then press Apply.

While in the Safe Mode, the Home screen displays the Security, Panic, and

 

2.

Press the OK icon.

Message Icons. A message !SAFE MODE! is displayed at the lower left

 

 

side of the screen.

 

3. To exit, press the safe mode bar and press

The keypad resets and restarts in the Safe Mode.

 

 

Yes to return to Normal Mode.

 

In the rare event that the keypad cannot successfully communicate in its graphic mode with the control panel, the Safe Mode is a backup mode that ensures that you can communicate with your system.

In this mode, the keypad operates much like a standard non-graphic keypad so that you can control your system until the problem is corrected.

If this situation occurs, the keypad presents you with a message of “Problems detected. Start Keypad in Safe Mode?” and requests a “Yes” or “No” response. If you answer with “Yes”, the keypad enters into the Safe Mode. If you answer with “No”, the keypad tries to communicate with the panel again. After 3 consecutive times of receiving no response, the keypad enters the Safe Mode automatically.

Note: Use care when providing the “Yes” or “No” response. Pressing the screen outside the prescribed area may cause the background to come to the front. If this occurs, the Yes/No message that disappeared times-out in 30 seconds even though it is not visible. Then the keypad resets into the Normal Mode (or Safe Mode if this is the third time that the warning message appeared).

Note that this is a limited mode of operation. While in this mode:

You can use the Security icon to access the Console Emulation Mode of operation to try to clear your faults, disarm the system, or enter additional Alpha Keypad commands specified in your panel User Guide. You can perform almost all functions that you can perform from a standard non-graphic alpha keypad.

You can press the “Panic” key and generate Emergency Messages as defined in the panel's home partition for this keypad.

The Armed and Ready LEDs on the front of the keypad indicates the keypad’s home partition status. The Message LED (on models with Voice feature) or Trouble LED (on models without Voice feature) is not active in the Safe Mode.

The Chime mode functions in the Safe Mode.

When an alarm occurs in the Safe Mode, it is displayed on the Console mode screen only and is not shown on the Home screen.

Z-Wave Scenes do not function in Safe Mode.

28

Page 28
Image 28
Honeywell 800-08091V3 Select Safe Mode and then press Apply, Press the OK icon, To exit, press the safe mode bar and press

800-08091V3 specifications

The Honeywell 800-08091V3 is a state-of-the-art control panel component that is recognized for its outstanding performance in the realm of security and monitoring systems. Designed to enhance the capabilities of Honeywell’s powerhouse security solutions, this product boasts a variety of features and technological advancements that ensure reliability and efficiency in protecting both residential and commercial properties.

One of the primary features of the Honeywell 800-08091V3 is its intuitive user interface, which allows for seamless navigation and easy access to critical information. The panel is designed with usability in mind, providing users with a straightforward means to monitor their security systems. This emphasis on user experience extends to the programming and customization options available, enabling users to tailor settings according to their specific needs.

Technologically, the Honeywell 800-08091V3 employs advanced communication protocols that ensure rapid data transmission and connectivity. It supports both wired and wireless communication, enhancing its versatility in various installations. This feature is particularly crucial for businesses or homeowners looking to implement a robust security system without the limitations of traditional wiring methods.

The Honeywell 800-08091V3 is also compatible with a wide range of security devices, including sensors, alarms, and surveillance cameras. This compatibility allows for an integrated system that can centralize control and monitoring, significantly improving response times and situational awareness. Its ability to interface with additional Honeywell products provides users with the flexibility to expand their security solutions as needs change.

In terms of characteristics, the Honeywell 800-08091V3 is designed for durability and longevity. It features a rugged construction that withstands environmental factors, making it suitable for both indoor and outdoor installations. Moreover, its power management capabilities ensure that the system remains operational during power outages, providing continuous protection without interruption.

Overall, the Honeywell 800-08091V3 exemplifies a commitment to innovation in security technology. Its key features, like an easy-to-use interface, advanced communication capabilities, extensive compatibility with other security devices, and robust construction, make it an ideal choice for those seeking a reliable and efficient security solution. Whether for home use or larger commercial applications, the Honeywell 800-08091V3 stands out as a prime example of modern security technology, ensuring peace of mind for users everywhere.