Introduction to Security System Operation

You can arm the system in one of three arming modes: Away, Stay, and Night. The following table lists the three different arming modes and the results of each.

FEATURES FOR EACH ARMING MODE

Arming

FUNCTION

Exit

Entry

Perimeter

Interior

Mode

 

Delay

Delay

Armed

Armed

 

 

 

 

 

 

 

 

AWAY

Press to arm when no one is staying on the

Yes

Yes

Yes

Yes

premises. When armed in AWAY, the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

system sounds an alarm if a protected door

 

 

 

 

 

 

 

or window is opened, or if any movement is

 

 

 

 

 

 

 

detected inside the premises.

 

 

 

 

 

 

 

 

 

 

 

 

STAY

Press to arm when you are staying home,

Yes

Yes

Yes

No

but might expect someone to use the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

entrance door later.

 

 

 

 

 

 

 

When armed in STAY, the system sounds

 

 

 

 

 

 

 

 

 

 

 

 

 

 

an alarm if a protected door or window is

 

 

 

 

 

 

 

 

 

 

 

 

 

 

opened, but you may otherwise move freely

 

 

 

 

 

 

 

throughout the premises.

 

 

 

 

 

 

 

 

 

 

 

 

NIGHT

Press to arm when you are staying home

Yes

Yes (set for Away or

Yes

Yes (set for Away or

and do not expect anyone to use the

 

 

 

 

 

 

 

Maximum Mode)

 

 

 

entrance door. Your installer may have

 

Stay Mode)

 

 

 

 

 

 

No (set for Stay or Instant

 

 

 

configured NIGHT Mode differently; have

 

No (set for Instant or

 

 

 

 

 

 

Mode)

 

 

 

the installer describe the actual settings of

 

Maximum Mode)

 

 

 

 

 

 

See Night Mode note below

 

 

 

this mode.

 

 

 

 

 

 

 

 

 

 

Note: Night Mode (on Residential Panels Only) arms all perimeter zones plus all zones listed in Zone List 5.

Important: On Commercial systems, “Away Auto Stay” mode is shown as “Away” mode (with all zones monitored). However, some interior zones may not be armed.

Note: The Voice Status Icon (Introduction to Security System OperationManual backgroundManual background ) indicates the Voice feature. Press the Voice Status Icon to hear system status. Wait 3 seconds and press again to hear Zone Faults or Trouble conditions. Voice status will annunciate even if Voice mode and Chime mode are disabled. Note that the Voice feature must be enabled (by the installer) for this icon to function correctly during an alarm condition.

Note: There is a communicator delay of 30 seconds. This delay will prevent a report to the central station if the control panel is disarmed within 30 seconds after an intrusion alarm is triggered. This delay can be removed, or it can be increased up to 45 seconds at the option of the user by consulting with the installer. Note that emergency, carbon monoxide, and fire-type alarms are normally reported without delay.

10